EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Physiological liver microtissue 384-well microplate system for preclinical hepatotoxicity assessment of therapeutic small molecule drugs

Lola Fäs, Minjun Chen iD, Weida Tong iD, Friederike Wenz, Nicola J Hewitt iD, Monika Tu, Katarzyna Sanchez, Natalia Zapiórkowska-Blumer, Hajnalka Varga, Karolina Kaczmarska, Maria Vittoria Colombo, Bruno G H Filippi iD

Toxicological Sciences · 01.01.2025 · 203 (1) · 79-87

DOI: 10.1093/toxsci/kfae123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Toxicological Sciences, online erschienen am 14.10.2024. Verfasst von Lola Fäs und 11 weiteren Autor:innen. Beteiligte Einrichtung: InSphero AG, CH-8952 Schlieren, Switzerland. Hauptthemen laut MEDLINE: Chemical and Drug Induced Liver Injury, Liver, Drug Evaluation, Preclinical. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Hepatotoxicity can lead to the discontinuation of approved or investigational drugs. The evaluation of the potential hepatoxicity of drugs in development is challenging because current models assessing this adverse effect are not always predictive of the outcome in human beings. Cell lines are routinely used for early hepatotoxicity screening, but to improve the detection of potential hepatotoxicity, in vitro models that better reflect liver morphology and function are needed. One such promising model is human liver microtissues. These are spheroids made of primary human parenchymal and nonparenchymal liver cells, which are amenable to high throughput screening. To test the predictivity of this model, the cytotoxicity of 152 FDA (US Food & Drug Administration)-approved small molecule drugs was measured as per changes in ATP content in human liver microtissues incubated in 384-well microplates. The results were analyzed with respect to drug label information, drug-induced liver injury (DILI) concern class, and drug class. The threshold IC50ATP-to-Cmax ratio of 176 was used to discriminate between safe and hepatotoxic drugs. “vMost-DILI-concern” drugs were detected with a sensitivity of 72% and a specificity of 89%, and “vMost-DILI-concern” drugs affecting the nervous system were detected with a sensitivity of 92% and a specificity of 91%. The robustness and relevance of this evaluation were assessed using a 5-fold cross-validation. The good predictivity, together with the in vivo-like morphology of the liver microtissues and scalability to a 384-well microplate, makes this method a promising and practical in vitro alternative to 2D cell line cultures for the early hepatotoxicity screening of drug candidates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Chemical and Drug Induced Liver InjuryLiverDrug Evaluation, PreclinicalHumansAdenosine TriphosphateHigh-Throughput Screening AssaysSpheroids, CellularToxicity TestsHepatocytesCells, CulturedSmall Molecule Libraries

Stichwörter der Autor:innen

DILIdrug safetydrug-induced liver injurymicrophysiological systemspheroid cultures

Substanzen

Adenosine TriphosphateSmall Molecule Libraries

Autor:innen und Institutionen

  • InSphero AG, CH-8952 Schlieren, Switzerland.
  • Division of Bioinformatics and Biostatistics, National Center for Toxicological Research (NCTR), U.S. Food and Drug Administration, Jefferson, AR 72079, United States.
  • Scientific Writing Services, DE-64390 Erzhausen, Germany.

ORCID-Profile: Minjun Chen, Weida Tong, Nicola J Hewitt, Bruno G H Filippi

Zitieren

APA

Fäs, L., Chen, M., Tong, W., Wenz, F., Hewitt, N. J., Tu, M., Sanchez, K., Zapiórkowska-Blumer, N., Varga, H., Kaczmarska, K., Colombo, M. V., & Filippi, B. G. H. (2025). Physiological liver microtissue 384-well microplate system for preclinical hepatotoxicity assessment of therapeutic small molecule drugs. Toxicological Sciences, 203(1), 79-87. https://doi.org/10.1093/toxsci/kfae123

Vancouver

Fäs L, Chen M, Tong W, Wenz F, Hewitt NJ, Tu M, et al. Physiological liver microtissue 384-well microplate system for preclinical hepatotoxicity assessment of therapeutic small molecule drugs. Toxicological Sciences. 2025;203(1):79-87. doi:10.1093/toxsci/kfae123

BibTeX
@article{Fs2025,
  author = {Fäs, Lola and Chen, Minjun and Tong, Weida and Wenz, Friederike and Hewitt, Nicola J and Tu, Monika and Sanchez, Katarzyna and Zapiórkowska-Blumer, Natalia and Varga, Hajnalka and Kaczmarska, Karolina and Colombo, Maria Vittoria and Filippi, Bruno G H},
  title = {Physiological liver microtissue 384-well microplate system for preclinical hepatotoxicity assessment of therapeutic small molecule drugs},
  journal = {Toxicological Sciences},
  year = {2025},
  volume = {203},
  number = {1},
  pages = {79--87},
  doi = {10.1093/toxsci/kfae123}
}
Kostenlos starten →