Refining sleep staging accuracy: transfer learning coupled with scorability models
SLEEP · 08.11.2024 · 47 (11)
DOI: 10.1093/sleep/zsae202 ↗Kurz gefasst
Fachartikel in der Zeitschrift SLEEP, online erschienen am 31.08.2024. Verfasst von Wolfgang Ganglberger und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA, USA. Hauptthemen laut MEDLINE: Polysomnography, Sleep Stages. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NINDS NIH HHS, NIA NIH HHS, NHLBI NIH HHS.
Abstract (Originalsprache)
Study Objectives This study aimed to (1) improve sleep staging accuracy through transfer learning (TL), to achieve or exceed human inter-expert agreement and (2) introduce a scorability model to assess the quality and trustworthiness of automated sleep staging.
Methods
A deep neural network (base model) was trained on a large multi-site polysomnography (PSG) dataset from the United States. TL was used to calibrate the model to a reduced montage and limited samples from the Korean Genome and Epidemiology Study (KoGES) dataset. Model performance was compared to inter-expert reliability among three human experts. A scorability assessment was developed to predict the agreement between the model and human experts.
Results
Initial sleep staging by the base model showed lower agreement with experts (κ = 0.55) compared to the inter-expert agreement (κ = 0.62). Calibration with 324 randomly sampled training cases matched expert agreement levels. Further targeted sampling improved performance, with models exceeding inter-expert agreement (κ = 0.70). The scorability assessment, combining biosignal quality and model confidence features, predicted model-expert agreement moderately well (R² = 0.42). Recordings with higher scorability scores demonstrated greater model-expert agreement than inter-expert agreement. Even with lower scorability scores, model performance was comparable to inter-expert agreement.
Conclusions
Fine-tuning a pretrained neural network through targeted TL significantly enhances sleep staging performance for an atypical montage, achieving and surpassing human expert agreement levels. The introduction of a scorability assessment provides a robust measure of reliability, ensuring quality control and enhancing the practical application of the system before deployment. This approach marks an important advancement in automated sleep analysis, demonstrating the potential for AI to exceed human performance in clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, Beth Israel Deaconess Medical Center, Boston, MA, USA.
- McCance Center for Brain Health, Massachusetts General Hospital, Boston, MA, USA.
- Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA.
- Biomedical Informatics & Neurology, Emory School of Medicine, Atlanta, GA, USA.
- Institute of Human Genomic Study, College of Medicine, Kore University, Seoul, Republic of Korea.
- Biomedical Research Center, Korea University Ansan Hospital, Ansan, Republic of Korea.
ORCID-Profile: Wolfgang Ganglberger, Robert J Thomas
Förderung
- NINDS NIH HHS
- NIA NIH HHS
- NHLBI NIH HHS
- NIH
- NSF
- Korea Disease Control and Prevention Agency
- Ministry of Education
- Korea Health Industry Development Institute
Zitieren
APA
Ganglberger, W., Nasiri, S., Sun, H., Kim, S., Shin, C., Westover, M. B., & Thomas, R. J. (2024). Refining sleep staging accuracy: transfer learning coupled with scorability models. SLEEP, 47(11). https://doi.org/10.1093/sleep/zsae202
Vancouver
Ganglberger W, Nasiri S, Sun H, Kim S, Shin C, Westover MB, et al. Refining sleep staging accuracy: transfer learning coupled with scorability models. SLEEP. 2024;47(11). doi:10.1093/sleep/zsae202
BibTeX
@article{Ganglberger2024,
author = {Ganglberger, Wolfgang and Nasiri, Samaneh and Sun, Haoqi and Kim, Soriul and Shin, Chol and Westover, M Brandon and Thomas, Robert J},
title = {Refining sleep staging accuracy: transfer learning coupled with scorability models},
journal = {SLEEP},
year = {2024},
volume = {47},
number = {11},
doi = {10.1093/sleep/zsae202}
}
EUVIMED