Fachartikel in der Zeitschrift SLEEP, online erschienen am 04.01.2022. Verfasst von Matteo Cesari und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Medical University of Innsbruck, Innsbruck, Austria. Hauptthemen laut MEDLINE: Sleep, REM, REM Sleep Behavior Disorder. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Austrian Science Fund.
Abstract (Originalsprache)
Study objectives To identify a fast and reliable method for rapid eye movement (REM) sleep without atonia (RWA) quantification.
Methods
We analyzed 36 video-polysomnographies (v-PSGs) of isolated REM sleep behavior disorder (iRBD) patients and 35 controls’ v-PSGs. Patients diagnosed with RBD had: i) RWA, quantified with a reference method, i.e. automatic and artifact-corrected 3-s Sleep Innsbruck Barcelona (SINBAR) index in REM sleep periods (RSPs, i.e. manually selected portions of REM sleep); and ii) v-PSG-documented RBD behaviors. We quantified RWA with other (semi)-automated methods requiring less human intervention than the reference one: the indices proposed by the SINBAR group (the 3-s and 30-s phasic flexor digitorum superficialis (FDS), phasic/”any”/tonic mentalis), and the REM atonia, short and long muscle activity indices (in mentalis/submentalis/FDS muscles). They were calculated in whole REM sleep (i.e. REM sleep scored following international guidelines), in RSPs, with and without manual artifact correction. Area under curves (AUC) discriminating iRBD from controls were computed. Using published cut-offs, the indices’ sensitivity and specificity for iRBD identification were calculated. Apnea-hypopnea index in REM sleep (AHIREM) was considered in the analyses.
Results
RWA indices from FDS muscles alone had the highest AUCs and all of them had 100% sensitivity. Without manual RSP selection and artifact correction, the “30-s phasic FDS” and the “FDS long muscle activity” had the highest specificity (85%) with AHIREM < 15/h. RWA indices were less reliable when AHIREM≥15/h.
Conclusions
If AHIREM<15/h, FDS muscular activity in whole REM sleep and without artifact correction is fast and reliable to rule out RWA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, Medical University of Innsbruck, Innsbruck, Austria.
- Neurology Service, Hospital Clínic of Barcelona, Barcelona, Spain.
- Biomedical Research Institute (IDIBAPS), Barcelona, Spain.
ORCID-Profile: Matteo Cesari, Ambra Stefani
Förderung
- Austrian Science Fund
Zitieren
APA
Cesari, M., Heidbreder, A., Gaig, C., Bergmann, M., Brandauer, E., Iranzo, A., Holzknecht, E., Santamaria, J., Högl, B., & Stefani, A. (2023). Automatic analysis of muscular activity in the flexor digitorum superficialis muscles: a fast screening method for rapid eye movement sleep without atonia. SLEEP, 46(3). https://doi.org/10.1093/sleep/zsab299
Vancouver
Cesari M, Heidbreder A, Gaig C, Bergmann M, Brandauer E, Iranzo A, et al. Automatic analysis of muscular activity in the flexor digitorum superficialis muscles: a fast screening method for rapid eye movement sleep without atonia. SLEEP. 2023;46(3). doi:10.1093/sleep/zsab299
BibTeX
@article{Cesari2023,
author = {Cesari, Matteo and Heidbreder, Anna and Gaig, Carles and Bergmann, Melanie and Brandauer, Elisabeth and Iranzo, Alex and Holzknecht, Evi and Santamaria, Joan and Högl, Birgit and Stefani, Ambra},
title = {Automatic analysis of muscular activity in the flexor digitorum superficialis muscles: a fast screening method for rapid eye movement sleep without atonia},
journal = {SLEEP},
year = {2023},
volume = {46},
number = {3},
doi = {10.1093/sleep/zsab299}
}
EUVIMED