Evaluation of occupational radiation exposure and safety practices among orthopedic surgeons using C-arm fluoroscopy: a preliminary study at a hospital in Palestine
Radiation Protection Dosimetry · 31.10.2026
DOI: 10.1093/rpd/ncag130 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 31.10.2026. Verfasst von Othman H Y Zalloum und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Mathematics and Physics, Palestine Polytechnic University, Dahiat Albaladia, P.O. box 198, Hebron, West Bank, Palestine. Die Arbeit nennt 38 Literaturangaben.
Abstract (Originalsprache)
This study presents, to our knowledge, the first dosimetric evaluation of occupational radiation exposure among orthopedic teams using C-arm fluoroscopy in Palestine. Thermoluminescence dosemeters (LiF:Mg,Ti, TLD-100) measured $H_{p}(10)$ and $H_{p}(0.07)$ at five anatomical sites on one surgeon during six procedures over 32 days: unshielded upper arms and shielded thyroid, chest, and gonads. The highest measured personal dose equivalent, $H_{p}(10)$, was 0.21 mSv at the unshielded right upper arm (30-day normalized value: 0.19 mSv; 11.7% of the monthly reference value derived from the International Commission on Radiological Protection annual occupational effective-dose limit). Although shielding reduced torso exposure, safety compliance was poor: 37% of staff consistently used lead aprons, 22.2% used thyroid shields, and 13.3% used dosemeters. These findings identify systemic gaps requiring enforced protection measures, routine monitoring, and staff education.
Autor:innen und Institutionen
- Department of Applied Mathematics and Physics, Palestine Polytechnic University, Dahiat Albaladia, P.O. box 198, Hebron, West Bank, Palestine.
- Al-Ahli Hospital, Farsh Al-Hawa, Hebron, West Bank, Palestine.
- Nuclear Energy and Radiation Regulatory Authority, Ministry of Health, Ramallah, West Bank, Palestine.
Zitieren
APA
Zalloum, O. H. Y., Sweiti, A., Haq Shaheen, A., Abo Sneneh, W., Abo Qweader, H., Odeh, R., Samuh, M. H., & Abu Safa, M. (2026). Evaluation of occupational radiation exposure and safety practices among orthopedic surgeons using C-arm fluoroscopy: a preliminary study at a hospital in Palestine. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag130
Vancouver
Zalloum OHY, Sweiti A, Haq Shaheen A, Abo Sneneh W, Abo Qweader H, Odeh R, et al. Evaluation of occupational radiation exposure and safety practices among orthopedic surgeons using C-arm fluoroscopy: a preliminary study at a hospital in Palestine. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag130
BibTeX
@article{Zalloum2026,
author = {Zalloum, Othman H Y and Sweiti, Ayman and Haq Shaheen, Abdul and Abo Sneneh, Wardeh and Abo Qweader, Hind and Odeh, Rafat and Samuh, Monjed H and Abu Safa, Mustafa},
title = {Evaluation of occupational radiation exposure and safety practices among orthopedic surgeons using C-arm fluoroscopy: a preliminary study at a hospital in Palestine},
journal = {Radiation Protection Dosimetry},
year = {2026},
doi = {10.1093/rpd/ncag130}
}
EUVIMED