Design and shielding effectiveness of adjustable modular medical radiation shelter
Radiation Protection Dosimetry · 30.10.2026
DOI: 10.1093/rpd/ncag128 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 30.10.2026. Verfasst von Si-Yuan Xu und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Information and Management, Guangxi Medical University, No. 336 Wuhua Avenue, Wuming District, Nanning, Guangxi Zhuang Autonomous Region 53…. Die Arbeit nennt 26 Literaturangaben. Gefördert von: China Undergraduate Innovation and Entrepreneurship Training Program.
Abstract (Originalsprache)
Medical imaging and radiotherapy rely on ionizing radiation that must be contained to protect staff, patients, and the public. Conventional shielding rooms use permanent, immobile concrete walls that are slow to build, leaving primary clinics and emergency sites poorly served. A modular, adjustable shelter was designed with six-sided composite walls combining barite–paraffin, a 24-cm water layer, and 0.5–20-mm lead plates for synergistic photon and neutron shielding, with S/Z-shaped penetrations to suppress joint leakage. Per the Chinese diagnostic radiology standard GBZ 130-2020, analytical models predicted shielding of 70–150 kVp diagnostic X-rays and 6 MV photons and an 11.9-fold reduction of 2 MeV neutrons. Geant4 Monte Carlo validation across six clinical scenarios (39 keV–1.47 MeV photons, 2 MeV neutrons) reproduced the model within 2.5% at 511 keV; exterior ambient dose equivalent H*(10) remained below 0.5 μSv h−1, satisfying the GBZ 130-2020 public dose limit. The shelter provides flexible, rapidly deployable protection for routine and emergency medical use.
Autor:innen und Institutionen
- School of Information and Management, Guangxi Medical University, No. 336 Wuhua Avenue, Wuming District, Nanning, Guangxi Zhuang Autonomous Region 530199, China.
- Department of Hydrology and Water Resources, Jiangsu Water Conservancy Engineering Science and Technology Consulting Co., Ltd., No. 9 Shanghai Road, Gulou District, Nanjing 210029, Jiangsu Province, P.R. China.
ORCID-Profile: Jing-Wen Ling
Förderung
- China Undergraduate Innovation and Entrepreneurship Training Program
Zitieren
APA
Xu, S. Y., Ling, J. W., Tu, J. M., Liu, P., & Liu, L. (2026). Design and shielding effectiveness of adjustable modular medical radiation shelter. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag128
Vancouver
Xu SY, Ling JW, Tu JM, Liu P, Liu L. Design and shielding effectiveness of adjustable modular medical radiation shelter. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag128
BibTeX
@article{Xu2026,
author = {Xu, Si-Yuan and Ling, Jing-Wen and Tu, Jin-Mei and Liu, Ping and Liu, Liang},
title = {Design and shielding effectiveness of adjustable modular medical radiation shelter},
journal = {Radiation Protection Dosimetry},
year = {2026},
doi = {10.1093/rpd/ncag128}
}
EUVIMED