EUVIMEDEUVIMED entdecken
Crossref

Effect of 131I biodistribution on measurements using a scanning whole-body counter

Yuki Tamakuma iD, Naoko Fukuda, Osamu Kurihara iD, Naoki Matsuda, Yu Abe iD, Sumi Yokoyama iD

Radiation Protection Dosimetry · 2026

DOI: 10.1093/rpd/ncag069 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Yuki Tamakuma und 5 weiteren Autor:innen. Beteiligte Einrichtung: Center for Radiation Research and Education, Nagasaki University, 1-12-4 Sakamoto, Nagasaki, Nagasaki 852-8523, Japan. Hauptthemen laut MEDLINE: Iodine Radioisotopes, Whole-Body Counting, Thyroid Gland, Radiation Monitoring. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To validate the thyroid dose assessment performed at Nagasaki University after the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, the influence of 131I biodistribution on the direct in-vivo counting measurements by a scanning whole-body counter with two NaI(Tl) detectors was evaluated by a Monte Carlo simulation. The peak efficiency for gamma rays from 131I was calculated for the Bottle-Manikin Absorption (BOMAB) phantom and International Commission on Radiological Protection voxel phantom with a uniform radionuclide distribution in the body and a localized distribution in the thyroid. The ratio of scan peak efficiencies for the BOMAB phantom with the uniform and localized distribution was 1.17 (localized/uniform), while that for the voxel phantom was 1.00. For the voxel phantom, a shielding by the head and tissues covering thyroid reduced the scan peak efficiency for the localized source, resulting in a negligible difference in peak efficiency between the source distributions. The assumption of a completely localized thyroid source is suggested to result in an underestimation within approximately 4% in residual activity assessment, considering 131I biodistribution calculated using ratios of physicochemical forms reported after the FDNPP accident, which represents a scenario with the maximum uncertainty. Consequently, the influence of 131I biodistribution on the scanning whole-body counting was negligibly small under the present conditions, partly due to the detector arrangement with two NaI(Tl) detectors positioned above and below the subject.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Iodine RadioisotopesWhole-Body CountingThyroid GlandRadiation MonitoringMonte Carlo MethodHumansPhantoms, ImagingTissue DistributionFukushima Nuclear AccidentRadiation DosageComputer SimulationSodium Iodide

Substanzen

Iodine RadioisotopesIodine-131Sodium Iodide

Autor:innen und Institutionen

  • Center for Radiation Research and Education, Nagasaki University, 1-12-4 Sakamoto, Nagasaki, Nagasaki 852-8523, Japan.
  • Department of Radiation Biology and Protection, Radiation Risk Control Unit, Atomic Bomb Disease Institute, Nagasaki University, 1-12-4 Sakamoto, Nagasaki, Nagasaki 852-8523, Japan.
  • Department of Radiation Measurement and Dose Assessment, Institute of Radiological Science, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage, Chiba 263-8555, Japan.

ORCID-Profile: Yuki Tamakuma, Osamu Kurihara, Yu Abe, Sumi Yokoyama

Zitieren

APA

Tamakuma, Y., Fukuda, N., Kurihara, O., Matsuda, N., Abe, Y., & Yokoyama, S. (2026). Effect of 131I biodistribution on measurements using a scanning whole-body counter. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag069

Vancouver

Tamakuma Y, Fukuda N, Kurihara O, Matsuda N, Abe Y, Yokoyama S. Effect of 131I biodistribution on measurements using a scanning whole-body counter. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag069

BibTeX
@article{Tamakuma2026,
  author = {Tamakuma, Yuki and Fukuda, Naoko and Kurihara, Osamu and Matsuda, Naoki and Abe, Yu and Yokoyama, Sumi},
  title = {Effect of 131I biodistribution on measurements using a scanning whole-body counter},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  doi = {10.1093/rpd/ncag069}
}
Kostenlos starten →