EUVIMEDEUVIMED entdecken
Crossref

Effect of analytical factors on the determination of gross alpha/beta activity in drinking water using liquid scintillation counting

Zhimo Chen, Liangliang Yin, Cen Shi, Yuhan Xie, Yuxin Qian, Yanqin Ji iD

Radiation Protection Dosimetry · 11.08.2026 · 202 (13) · 1033-1042

DOI: 10.1093/rpd/ncag041 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 30.04.2026. Verfasst von Zhimo Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Diseas…. Hauptthemen laut MEDLINE: Scintillation Counting, Water Pollutants, Radioactive, Drinking Water, Alpha Particles. Die Arbeit nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A method for the determination of gross alpha and beta activity concentrations in drinking water samples was established using liquid scintillation counting (LSC) through a series of batch experiments on water samples spiked with 241Am and 90Sr/90Y. Counting windows were set to cover the full energy spectrum. α/β discrimination was investigated considering the use of calibration sources, spillover, and additional factors (e.g. scintillation cocktail type, acidic media, pH, sample-to-cocktail volume ratio) and was optimized. The optimized Pulse Shape Analysis value was set to 120 (τα + τβ = 5.511%). The impact of the total dissolved solids and sample-to-scintillation liquid volume ratio on counting efficiency was investigated. After optimization, the gross alpha and beta counting efficiencies were 26.6% and 37.6%, respectively. The measurement results demonstrated good agreement between the values obtained by LSC and the solid scintillation counting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Scintillation CountingWater Pollutants, RadioactiveDrinking WaterAlpha ParticlesBeta ParticlesStrontium RadioisotopesAmericiumYttrium RadioisotopesRadiation MonitoringCalibration

Substanzen

Water Pollutants, RadioactiveDrinking WaterStrontium RadioisotopesAmericiumYttrium RadioisotopesAmericium-241Yttrium-90Strontium-90

Autor:innen und Institutionen

  • Key Laboratory of Radiological Protection and Nuclear Emergency, China CDC, National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing 100088, China.

ORCID-Profile: Yanqin Ji

Zitieren

APA

Chen, Z., Yin, L., Shi, C., Xie, Y., Qian, Y., & Ji, Y. (2026). Effect of analytical factors on the determination of gross alpha/beta activity in drinking water using liquid scintillation counting. Radiation Protection Dosimetry, 202(13), 1033-1042. https://doi.org/10.1093/rpd/ncag041

Vancouver

Chen Z, Yin L, Shi C, Xie Y, Qian Y, Ji Y. Effect of analytical factors on the determination of gross alpha/beta activity in drinking water using liquid scintillation counting. Radiation Protection Dosimetry. 2026;202(13):1033-1042. doi:10.1093/rpd/ncag041

BibTeX
@article{Chen2026,
  author = {Chen, Zhimo and Yin, Liangliang and Shi, Cen and Xie, Yuhan and Qian, Yuxin and Ji, Yanqin},
  title = {Effect of analytical factors on the determination of gross alpha/beta activity in drinking water using liquid scintillation counting},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  volume = {202},
  number = {13},
  pages = {1033--1042},
  doi = {10.1093/rpd/ncag041}
}
Kostenlos starten →