A JavaScript-based computational method for predicting decay activity of 131I: development, benchmark- and phantom-based assessment of an open-access research tool
Radiation Protection Dosimetry · 06.07.2026 · 202 (11) · 892-903
DOI: 10.1093/rpd/ncag024 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 23.03.2026. Verfasst von Ludovico M Garau und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Medicine, Santa Maria della Misericordia University Hospital, Piazzale Santa Maria della Misericordia, 15, 33100, Udine, Italy. Hauptthemen laut MEDLINE: Iodine Radioisotopes, Phantoms, Imaging, Radiometry, Software. Die Arbeit nennt 40 Literaturangaben.
Abstract (Originalsprache)
This study investigated the use of JavaScript (JS) to develop and test an open-access method, provided as a research resource, for predicting the decay and cumulative activity of iodine-131 (131I). A client-side JS engine was implemented to simulate decay using mono-exponential and piecewise multi-segmented models. Built-in JS functions were used to perform logarithmic and exponential operations. The tool’s performance was validated against ion-chamber measurements from a thyroid phantom containing a pre-calibrated 131I capsule; moreover, measurement reliability was assessed. The phantom test showed a mean absolute error of 0.010 μSv/h for the mono-exponential model and 0.008 μSv/h for the multi-segmented model. The intraclass correlation coefficient (ICC) demonstrated excellent inter-observer agreement (ICC range: 0.998–0.999), while the mean intra-observer difference was 0.3% (SD = 0.2%; range: 0.1%–0.6%). By quantifying instrument-related error in advance, future studies may more confidently isolate biological variability, thereby supporting the robustness of patient-level interpretation and dose-prediction models.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Nuclear Medicine, Santa Maria della Misericordia University Hospital, Piazzale Santa Maria della Misericordia, 15, 33100, Udine, Italy.
- Department of Electrical, Computer and Biomedical Engineering, Pavia University, Via A. Ferrata, 5, 27100 Pavia, Italy.
- Department of Medical Physics, Santa Maria della Misericordia University Hospital, Piazzale Santa Maria della Misericordia, 15, 33100, Udine, Italy.
ORCID-Profile: Ludovico M Garau
Zitieren
APA
Garau, L. M., Rosso, V., Bastianutti, L., Schiattarella, S., & Di Gregorio, F. (2026). A JavaScript-based computational method for predicting decay activity of 131I: development, benchmark- and phantom-based assessment of an open-access research tool. Radiation Protection Dosimetry, 202(11), 892-903. https://doi.org/10.1093/rpd/ncag024
Vancouver
Garau LM, Rosso V, Bastianutti L, Schiattarella S, Di Gregorio F. A JavaScript-based computational method for predicting decay activity of 131I: development, benchmark- and phantom-based assessment of an open-access research tool. Radiation Protection Dosimetry. 2026;202(11):892-903. doi:10.1093/rpd/ncag024
BibTeX
@article{Garau2026,
author = {Garau, Ludovico M and Rosso, Veronica and Bastianutti, Livio and Schiattarella, Stefano and Di Gregorio, Fernando},
title = {A JavaScript-based computational method for predicting decay activity of 131I: development, benchmark- and phantom-based assessment of an open-access research tool},
journal = {Radiation Protection Dosimetry},
year = {2026},
volume = {202},
number = {11},
pages = {892--903},
doi = {10.1093/rpd/ncag024}
}
EUVIMED