EUVIMEDEUVIMED entdecken
Crossref

Safety analysis of the NuScale Small Modular Reactor: steady-state qualification and small break loss of coolant accident simulation using RELAP5/SCDAPSIM3.4

Ahmed Hadjam iD, Djillali Saad, Amina Lyria Deghal Cheridi, Mohammed Bouaouina, Ahmed Dahia, Amel Dadda

Radiation Protection Dosimetry · 2026

DOI: 10.1093/rpd/ncag020 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2026. Verfasst von Ahmed Hadjam und 5 weiteren Autor:innen. Beteiligte Einrichtung: Thermal-hydraulic Department, Nuclear Research Center of Birine, B.P. 180 Ain Oussera, 17200 Djelfa, Algeria. Hauptthemen laut MEDLINE: Nuclear Reactors, Radioactive Hazard Release, Radiation Monitoring. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 9 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a comprehensive safety analysis of the NuScale Small Modular Reactor, a next-generation nuclear technology. The NuScale design emphasizes enhanced safety, flexibility, and efficiency, achieved through a natural circulation cooling system and robust passive safety functions. The analysis is conducted using the RELAP5/SCDAPSIM3.4 system code for high-fidelity thermal–hydraulic simulations. The first part details the steady-state qualification of the reactor model, a crucial step to establish a reliable baseline for normal operation and subsequent accident analyses. The study confirms the model’s accuracy against key design parameters including temperature distributions, coolant flow rates, and system pressure validating its predictive capability. Building upon this qualified model, the second part investigates a severe beyond-design-basis accident scenario. The initiating event is the inadvertent opening of one Reactor Vent Valve, leading to an inside containment Small Break Loss of Coolant Accident. This breach is compounded by the postulated total failure of both the Emergency Core Cooling System and the Decay Heat Removal System, creating a fully unmitigated scenario. The progression of this severe accident, simulated for a duration of 500 s, critically assesses the reactor’s passive safety features and inherent resilience. The system’s response is analyzed in detail, with key findings showing a consistent behavior comparable to the results of similar scenarios documented in the literature.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nuclear ReactorsRadioactive Hazard ReleaseRadiation MonitoringComputer SimulationEquipment DesignHumans

Autor:innen und Institutionen

  • Thermal-hydraulic Department, Nuclear Research Center of Birine, B.P. 180 Ain Oussera, 17200 Djelfa, Algeria.

ORCID-Profile: Ahmed Hadjam

Zitieren

APA

Hadjam, A., Saad, D., Deghal Cheridi, A. L., Bouaouina, M., Dahia, A., & Dadda, A. (2026). Safety analysis of the NuScale Small Modular Reactor: steady-state qualification and small break loss of coolant accident simulation using RELAP5/SCDAPSIM3.4. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncag020

Vancouver

Hadjam A, Saad D, Deghal Cheridi AL, Bouaouina M, Dahia A, Dadda A. Safety analysis of the NuScale Small Modular Reactor: steady-state qualification and small break loss of coolant accident simulation using RELAP5/SCDAPSIM3.4. Radiation Protection Dosimetry. 2026. doi:10.1093/rpd/ncag020

BibTeX
@article{Hadjam2026,
  author = {Hadjam, Ahmed and Saad, Djillali and Deghal Cheridi, Amina Lyria and Bouaouina, Mohammed and Dahia, Ahmed and Dadda, Amel},
  title = {Safety analysis of the NuScale Small Modular Reactor: steady-state qualification and small break loss of coolant accident simulation using RELAP5/SCDAPSIM3.4},
  journal = {Radiation Protection Dosimetry},
  year = {2026},
  doi = {10.1093/rpd/ncag020}
}
Kostenlos starten →