EUVIMEDEUVIMED entdecken
Crossref

Evaluation of occupational equivalent doses to selected organs and tissues in veterinarians from scattered radiation during X-ray and CT examinations

Joaquín Jiménez iD, Jose A Corbacho iD, Pedro Escudero, Marta Púa, Coral Melchor

Radiation Protection Dosimetry · 2025

DOI: 10.1093/rpd/ncaf153 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Joaquín Jiménez und 4 weiteren Autor:innen. Beteiligte Einrichtung: Departamento de Medicina Animal, Facultad de Veterinaria, Universidad de Extremadura, Avda. Universidad, S/N, E-10003 Cáceres, Spain. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Radiation Protection, Occupational Exposure, Veterinarians. Die Arbeit nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluates the occupational equivalent doses to selected organs and tissues received by veterinary staff at the Veterinary Clinical Hospital of the University of Extremadura, where $\sim $7000 diagnostic imaging procedures (X-ray and computed tomography scans) are performed annually on patients of various sizes. Experiments were conducted with dosemeters positioned to simulate typical locations of veterinary operators during radiographic procedures under clinical conditions. Canine cadavers and equine anatomical specimens were used as animal patients, and scattered radiation exposure was measured at operator-relevant sites—including the hands, thorax, gonads, and eyes—both with and without protective equipment. The findings confirm that, with proper radioprotection measures, doses remain well below the legal limit (500, 50 and 20 mSv y$^{-1}$ for hands, eye lens and other tissues, respectively), even in worst-case scenarios—particularly during portable equine radiography exposure. However, it highlights the need for strict adherence to radiation safety protocols.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedRadiation ProtectionOccupational ExposureVeterinariansRadiation ExposureAnimalsRadiation DosageHorsesDogsHumansScattering, RadiationCadaverX-RaysRadiation MonitoringHand

Autor:innen und Institutionen

  • Departamento de Medicina Animal, Facultad de Veterinaria, Universidad de Extremadura, Avda. Universidad, S/N, E-10003 Cáceres, Spain.
  • Departamento de Física Aplicada, Centro Universitario de Mérida, Universidad de Extremadura, Avda. Santa Teresa de Jornet, 38, E-06800 Mérida, Badajoz, Spain.

ORCID-Profile: Joaquín Jiménez, Jose A Corbacho

Zitieren

APA

Jiménez, J., Corbacho, J. A., Escudero, P., Púa, M., & Melchor, C. (2025). Evaluation of occupational equivalent doses to selected organs and tissues in veterinarians from scattered radiation during X-ray and CT examinations. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf153

Vancouver

Jiménez J, Corbacho JA, Escudero P, Púa M, Melchor C. Evaluation of occupational equivalent doses to selected organs and tissues in veterinarians from scattered radiation during X-ray and CT examinations. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf153

BibTeX
@article{Jimnez2025,
  author = {Jiménez, Joaquín and Corbacho, Jose A and Escudero, Pedro and Púa, Marta and Melchor, Coral},
  title = {Evaluation of occupational equivalent doses to selected organs and tissues in veterinarians from scattered radiation during X-ray and CT examinations},
  journal = {Radiation Protection Dosimetry},
  year = {2025},
  doi = {10.1093/rpd/ncaf153}
}
Kostenlos starten →