Establishment and validation of a dose–response curve for semi-automated analysis of dicentric chromosomes induced by 60Co γ-rays
Radiation Protection Dosimetry · 2025
DOI: 10.1093/rpd/ncaf101 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Qian-Qian Meng und 7 weiteren Autor:innen. Beteiligte Einrichtung: China Institute for Radiation Protection (CIRP), 102 Xuefu Street, Taiyuan City, Shanxi Province, 030006, China. Hauptthemen laut MEDLINE: Radiometry, Chromosome Aberrations, Gamma Rays. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Shanxi Provincial Science and Technology Department.
Abstract (Originalsprache)
The dicentric chromosome assay serves as the “gold standard” for biodosimetry, playing a crucial role in rapid clinical decision-making during extensive nuclear radiation incidents. This study aimed to develop a semi-automated dose–response curve for the analysis of dicentric chromosomes induced by irradiation of human peripheral blood lymphocytes with 60Co gamma rays. Blood samples were collected from three healthy donors and subjected to irradiation, culture, and harvesting, following International Atomic Energy Agency standard protocols. The Metafer4 system, an automatic scoring system, was utilized to acquire images of the metaphase chromosome segregation phase, and the dose–response curve was constructed through automatic analysis of dicentric chromosomes supplemented by manual verification. The curve was subsequently validated through blind scoring. The results demonstrated that the semi-automated scoring method provides quick and precise dose estimations and offers a viable alternative to manual dicentric chromosome assay. This approach holds significant potential for application in the nuclear emergency management of large-scale radiological events.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- China Institute for Radiation Protection (CIRP), 102 Xuefu Street, Taiyuan City, Shanxi Province, 030006, China.
ORCID-Profile: Qian-Qian Meng
Förderung
- Shanxi Provincial Science and Technology Department
Zitieren
APA
Meng, Q. Q., Ren, Y., Zhang, Z. X., Li, X. Z., Zhang, X. Q., Liu, H. Y., Guo, Y. F., & Zhang, R. F. (2025). Establishment and validation of a dose–response curve for semi-automated analysis of dicentric chromosomes induced by 60Co γ-rays. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf101
Vancouver
Meng QQ, Ren Y, Zhang ZX, Li XZ, Zhang XQ, Liu HY, et al. Establishment and validation of a dose–response curve for semi-automated analysis of dicentric chromosomes induced by 60Co γ-rays. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf101
BibTeX
@article{Meng2025,
author = {Meng, Qian-Qian and Ren, Yue and Zhang, Zhong-Xin and Li, Xiao-Zhen and Zhang, Xiao-Quan and Liu, Hong-Yan and Guo, Yu-Feng and Zhang, Rui-Feng},
title = {Establishment and validation of a dose–response curve for semi-automated analysis of dicentric chromosomes induced by 60Co γ-rays},
journal = {Radiation Protection Dosimetry},
year = {2025},
doi = {10.1093/rpd/ncaf101}
}
EUVIMED