Radiation exposure reduction using an equalization filter during percutaneous coronary intervention: a preliminary study
Radiation Protection Dosimetry · 2025
DOI: 10.1093/rpd/ncaf062 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Nao Ichikawa und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Faculty of Health Science, Kobe Tokiwa University, 2-6-2 Otani-cho, Nagata-ku, Kobe, Hyogo 653-0838, Japan. Hauptthemen laut MEDLINE: Percutaneous Coronary Intervention, Radiation Exposure, Radiation Protection, Radiography, Interventional. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
This study aimed to evaluate radiation exposure reduction in patients and physicians with an equalization filter (EF) in percutaneous coronary intervention. An anthropomorphic phantom was placed on the examination table in the interventional fluoroscopy system. An ionization chamber was attached to the X-ray tube to measure the X-ray output. A solid-state survey meter was placed at the physician’s position. EF positions were defined as ‘Shallow’, ‘Deep’, ‘Both’, ‘Right’, and ‘Left’. The X-ray output and H*(10) with and without EFs were measured at 80–160 cm increments of 20 cm with 10 C-arm angulations. The air kerma was almost identical with and without EFs. The EF reduced kerma-area product and H*(10) by a maximum of 27.4%. The average H*(10) reduction of ‘Deep’ was larger than that of ‘Shallow’ in order of ‘Both’ > ‘Left’ > ‘Right’. EFs contribute to reducing patient and physician exposure while maintaining X-ray output.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiological Technology, Faculty of Health Science, Kobe Tokiwa University, 2-6-2 Otani-cho, Nagata-ku, Kobe, Hyogo 653-0838, Japan.
- Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima, Fukushima 960-1295, Japan.
- Department of Radiation Oncology, Shiga General Hospital, 5-4-30 Moriyama, Moriyama, Shiga 524-0022, Japan.
- Department of Radiology, Shiga General Hospital, 5-4-30 Moriyama, Moriyama, Shiga 524-0022, Japan.
- Department of Quantum Medical Technology, Graduate School of Medical Science, Kanazawa University, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 920-0942, Japan.
Zitieren
APA
Ichikawa, N., Fukuda, A., Hayashi, T., Hattori, Y., & Matsubara, K. (2025). Radiation exposure reduction using an equalization filter during percutaneous coronary intervention: a preliminary study. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf062
Vancouver
Ichikawa N, Fukuda A, Hayashi T, Hattori Y, Matsubara K. Radiation exposure reduction using an equalization filter during percutaneous coronary intervention: a preliminary study. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf062
BibTeX
@article{Ichikawa2025,
author = {Ichikawa, Nao and Fukuda, Atsushi and Hayashi, Takuma and Hattori, Yosuke and Matsubara, Kosuke},
title = {Radiation exposure reduction using an equalization filter during percutaneous coronary intervention: a preliminary study},
journal = {Radiation Protection Dosimetry},
year = {2025},
doi = {10.1093/rpd/ncaf062}
}
EUVIMED