Dose calculation in nuclear medicine with magnetic resonance imaging images using Monte Carlo method

Le Huy Vu, Nguyen Thi Phuong Thao, Nguyen Thien Trung, Pham Vo Trung Hau, Truong Thi Hong Loan iD

Radiation Protection Dosimetry · 2025

DOI: 10.1093/rpd/ncaf043 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Le Huy Vu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Nursing-Medical Technology, Pham Ngoc Thach University of Medicine, 2 Duong Quang Trung Street, District 10, Ho Chi Minh City, 72700, Viet…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Monte Carlo Method, Image Processing, Computer-Assisted, Nuclear Medicine. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, scientists have been trying to convert magnetic resonance imaging (MRI) images into computed tomography (CT) images for dose calculations while taking advantage of the benefits of MRI images. The main approaches for image conversion are bulk density, Atlas registration, and machine learning. These methods have limitations in accuracy and time consumption and require large datasets to convert images. In this study, the novel ‘voxels spawn voxels’ technique combined with the ‘orthonormalize’ feature in Carimas software was developed to build a conversion dataset from MRI intensity to Hounsfield unit value for some structural regions including gluteus maximus, liver, kidneys, spleen, pancreas, and colon. The original CT images and the converted MRI images were imported into the Geant4/Gamos software for dose calculation. It gives good results (<5%) in most organs except the intestine (18%).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingMonte Carlo MethodImage Processing, Computer-AssistedNuclear MedicineTomography, X-Ray ComputedHumansRadiation DosageSoftwarePhantoms, ImagingAlgorithms

Autor:innen und Institutionen

  • Faculty of Nursing-Medical Technology, Pham Ngoc Thach University of Medicine, 2 Duong Quang Trung Street, District 10, Ho Chi Minh City, 72700, Vietnam.
  • Department of Nuclear Physics, Faculty of Physics and Engineering Physics, University of Science, Ho Chi Minh City, 227 Nguyen Van Cu Street, District 5, Ho Chi Minh City, 72700, Vietnam.
  • Vietnam National University, Ho Chi Minh City, Linh Trung, Thu Duc, Ho Chi Minh City, 71351, Vietnam.
  • Nguyen Huu Huan High School, 1 Doan Ket Street, Binh Tho, Thu Duc, Ho Chi Minh City, 71351, Vietnam.
  • TechBase, 67 Le Loi Street, Ben Nghe, District 1, Ho Chi Minh City, 72700, Vietnam.
  • Ho Chi Minh City University of Education, 280 An Duong Vuong Street, Ho Chi Minh City, 72700, Vietnam.

ORCID-Profile: Truong Thi Hong Loan

Zitieren

APA

Vu, L. H., Thao, N. T. P., Trung, N. T., Hau, P. V. T., & Hong Loan, T. T. (2025). Dose calculation in nuclear medicine with magnetic resonance imaging images using Monte Carlo method. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf043

Vancouver

Vu LH, Thao NTP, Trung NT, Hau PVT, Hong Loan TT. Dose calculation in nuclear medicine with magnetic resonance imaging images using Monte Carlo method. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf043

BibTeX
@article{Vu2025,
  author = {Vu, Le Huy and Thao, Nguyen Thi Phuong and Trung, Nguyen Thien and Hau, Pham Vo Trung and Hong Loan, Truong Thi},
  title = {Dose calculation in nuclear medicine with magnetic resonance imaging images using Monte Carlo method},
  journal = {Radiation Protection Dosimetry},
  year = {2025},
  doi = {10.1093/rpd/ncaf043}
}
Kostenlos starten →