EUVIMEDEUVIMED entdecken
Systematische Übersicht

A survey on the determination of diagnostic reference levels in analog and digital radiography in Iran: a systematic literature review

Mehdi Ghazizadeh, Mohammad Reza Deevband, Mohammad Reza Kardan, Meysam Tavakoli iD

Radiation Protection Dosimetry · 2025

DOI: 10.1093/rpd/ncaf030 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Mehdi Ghazizadeh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, No. 24, Aarabi St, Yam…. Hauptthemen laut MEDLINE: Diagnostic Reference Levels, Radiographic Image Enhancement, Radiation Protection, Radiation Exposure. Die Arbeit nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Although ionizing radiation plays a key role in both diagnosis and treatment, it brings potential risks, including incidence of cancer. Diagnostic Reference Level (DRL) is described as a tool to optimize the protection in the medical exposure for diagnostic procedures. The objective of this study is to propose a new method to calculate DRL by reviewing a series of articles which are published on the DRL in radiography. Materials and Methods The study analyzed 16 articles in the last ten years including published data on National and Local DRLs. The weighted mean method was used to propose unique quantities such as the entrance skin dose (ESD) or Entrance Surface Air Kerma (ESAK), and dose area product (DAP) as national DRL.

Results

The results showed that there were differences in dose values among diagnostic radiology centers for different examinations. The study provides valuable information to calculate national DRL.

Conclusion

The weighted mean of the ESD or ESAK and DAP values has been proposed as a new method for calculating national DRL values, which is considered the significant difference in statistical population and number of articles.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diagnostic Reference LevelsRadiographic Image EnhancementRadiation ProtectionRadiation ExposureHumansIranRadiation Dosage

Autor:innen und Institutionen

  • Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, No. 24, Aarabi St, Yaman St, Velenjak, P.O. Box: 19395-4763, Tehran, 1985717413, Iran.
  • Safety Research Institute Nuclear Science and Technology Research Institute Tehran, Tehran, 1439955933, Iran.
  • Department of Radiation Oncology, Winship Cancer Institute, Emory University Atlanta Georgia, 550 Peachtree St NE, Atlanta, GA 30308, United States.

ORCID-Profile: Meysam Tavakoli

Zitieren

APA

Ghazizadeh, M., Deevband, M. R., Kardan, M. R., & Tavakoli, M. (2025). A survey on the determination of diagnostic reference levels in analog and digital radiography in Iran: a systematic literature review. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf030

Vancouver

Ghazizadeh M, Deevband MR, Kardan MR, Tavakoli M. A survey on the determination of diagnostic reference levels in analog and digital radiography in Iran: a systematic literature review. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf030

BibTeX
@article{Ghazizadeh2025,
  author = {Ghazizadeh, Mehdi and Deevband, Mohammad Reza and Kardan, Mohammad Reza and Tavakoli, Meysam},
  title = {A survey on the determination of diagnostic reference levels in analog and digital radiography in Iran: a systematic literature review},
  journal = {Radiation Protection Dosimetry},
  year = {2025},
  doi = {10.1093/rpd/ncaf030}
}
Kostenlos starten →