Surgical staff doses during liver transplantation on a patient undergoing Lu-177-DOTATATE radioligand therapy
Radiation Protection Dosimetry · 2025
DOI: 10.1093/rpd/ncaf026 ↗Kurz gefasst
Fallbericht in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Faustino Bonutti und 8 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics Department, University Hospital, Piazzale Santa Maria della Misericordia, 15, 33100 Udine (UD), Italy. Hauptthemen laut MEDLINE: Liver Transplantation, Occupational Exposure, Organometallic Compounds, Octreotide. Die Arbeit nennt 4 Literaturangaben.
Abstract (Originalsprache)
The radiation doses received by the surgical staff during a lifesaving liver transplantation on a female patient, who had received the third cycle of Lu-177-DOTATATE 6 days prior to the surgery, are presented. Thermoluminescent personal dosemeters (TLDs), calibrated in Hp (10) and Hp (0.07), were distributed among the surgical team to assess the effective doses. Finger TLDs, calibrated in Hp (0.07), were specifically provided to the surgeons for hand dose assessment. Ambient dose equivalent rates in air were measured at various distances from the patient, both before and after the liver removal. The results indicate that the overall personal doses were below the minimum detectable dose, with the exception of the first surgeon’s finger dose. Additionally, the activity of the liver lesion was measured using a germanium solid-state detector to determine the total activity in the organ at the time of surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Medical Physics Department, University Hospital, Piazzale Santa Maria della Misericordia, 15, 33100 Udine (UD), Italy.
- Medical Physics Department, Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, Via Franco Gallini, 2, 33081 Aviano (PN), Italy.
- General Surgery Clinic and Liver-Kidney Transplant Center, Department of General Surgery, University Hospital, Piazzale Santa Maria della Misericordia, 15, 33100 Udine (UD), Italy.
- Department of Medicine, University of Udine, Via Colugna, 50, 33100 Udine (UD), Italy.
- Institute of Pathological Anatomy, University Hospital, Piazzale Santa Maria della Misericordia, 15, 33100 Udine (UD), Italy.
- Radiation Oncology Department, Centro di Riferimento Oncologico di Aviano (CRO) IRCCS, Via Franco Gallini, 2, 33081, Aviano (PN), Italy.
ORCID-Profile: Cinzia Avigo
Zitieren
APA
Bonutti, F., Avigo, C., Cherchi, V., Baccarani, U., Scarpa, E., Mangogna, A., Fanetti, G., Borsatti, E., & Drigo, A. (2025). Surgical staff doses during liver transplantation on a patient undergoing Lu-177-DOTATATE radioligand therapy. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf026
Vancouver
Bonutti F, Avigo C, Cherchi V, Baccarani U, Scarpa E, Mangogna A, et al. Surgical staff doses during liver transplantation on a patient undergoing Lu-177-DOTATATE radioligand therapy. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf026