EUVIMEDEUVIMED entdecken
Crossref

Incorporating boron distribution variations in microdosimetric kinetic model-based relative biological effectiveness calculations for boron neutron capture therapy

Mingzhu Li, Changran Geng iD, Yang Han, Fada Guan, Yuanhao Liu, Diyun Shu, Xiaobin Tang

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae158 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Mingzhu Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China. Hauptthemen laut MEDLINE: Boron Neutron Capture Therapy, Relative Biological Effectiveness, Boron. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Natural Science Foundation of Jiangsu Province, National Natural Science Foundation of China, National Key Research and Development Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study introduces the MKM_B model, an approach derived from the MKM model, designed to evaluate the biological effectiveness of Boron Neutron Capture Therapy (BNCT) in the face of challenges from varying microscopic boron distributions. The model introduces a boron compensation factor, allowing for the assessment of compound Biological Effectiveness (CBE) values for different boron distributions. Utilizing the TOPAS simulation platform, the lineal energy spectrum of particles in BNCT was simulated, and the sensitivity of the MKM_B model to parameter variations and the influence of cell size on the model were thoroughly investigated. The CBE values for 10B-boronphenylalanine (BPA) and 10B-sodium (BSH) were determined to be 3.70 and 1.75, respectively. These calculations were based on using the nucleus radius of 2.5 μm and the cell radius of 5 μm while considering a 50% surviving fraction. It was observed that as cell size decreased, the CBE values for both BPA and BSH increased. Additionally, the model parameter rd was identified as having the most significant impact on CBE, with other parameters showing moderate effects. The development of the MKM_B model enables the accurate prediction of CBE under different boron distributions in BNCT. This model offers a promising approach to optimize treatment planning by providing increased accuracy in biological effectiveness.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Boron Neutron Capture TherapyRelative Biological EffectivenessBoronHumansKineticsBoron CompoundsPhenylalanineModels, BiologicalComputer SimulationRadiometryCell Size

Substanzen

BoronBoron CompoundsPhenylalanine

Autor:innen und Institutionen

  • Department of Nuclear Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing, 211106, China.
  • Joint International Research Laboratory on Advanced Particle Therapy, Nanjing University of Aeronautics and Astronautics, Nanjing, 211100, China.
  • Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut, 06530, United States.
  • Neuboron Medtech Ltd., Nanjing, Jiangsu, 211112, China.

ORCID-Profile: Changran Geng

Förderung

  • Natural Science Foundation of Jiangsu Province
  • National Natural Science Foundation of China
  • National Key Research and Development Program

Zitieren

APA

Li, M., Geng, C., Han, Y., Guan, F., Liu, Y., Shu, D., & Tang, X. (2024). Incorporating boron distribution variations in microdosimetric kinetic model-based relative biological effectiveness calculations for boron neutron capture therapy. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae158

Vancouver

Li M, Geng C, Han Y, Guan F, Liu Y, Shu D, et al. Incorporating boron distribution variations in microdosimetric kinetic model-based relative biological effectiveness calculations for boron neutron capture therapy. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae158

BibTeX
@article{Li2024,
  author = {Li, Mingzhu and Geng, Changran and Han, Yang and Guan, Fada and Liu, Yuanhao and Shu, Diyun and Tang, Xiaobin},
  title = {Incorporating boron distribution variations in microdosimetric kinetic model-based relative biological effectiveness calculations for boron neutron capture therapy},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae158}
}
Kostenlos starten →