EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Monte Carlo calculated photon interaction coefficients for several body tissues

Aycan Sengul, Ahmet Bozkurt

Radiation Protection Dosimetry · 04.04.2024 · 200 (5) · 487-495

DOI: 10.1093/rpd/ncae006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 07.02.2024. Verfasst von Aycan Sengul und 1 weiteren Autor:innen. Beteiligte Einrichtung: Vocational School of Health Services, Medical Imaging Program, Akdeniz University, Antalya 07058, Turkey. Hauptthemen laut MEDLINE: Photons. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Absorption of energy in body tissues because of radiation interactions may induce harmful outcomes such as cancer and hereditary effects due to a variety of damages in the integrity and activity of the cells. This study presents Monte Carlo calculated $\boldsymbol{\mu} /\boldsymbol{\rho}$, ${\boldsymbol{\mu}}_{\boldsymbol{en}}/\boldsymbol{\rho}$ and ${\boldsymbol{\mu}}_{\boldsymbol{tr}}/\boldsymbol{\rho}$ values of some common tissues and organs found in the human body (namely, adipose tissue, blood, bone-cortical, brain-grey/white matter, breast tissue, eye lens, lung tissue, muscle-skeletal, ovary, soft tissue and testes) as well as water for comparison purposes. The simulation model involves a monoenergetic point source producing a pencil beam where, depending on the parameter under study, particle flux, energy flux or absorbed dose from photon interactions are scored in the range of 10 keV to 20 MeV energy. The simulations were performed using the Monte Carlo package MCNP6.1 and provided $\boldsymbol{\mu} /\boldsymbol{\rho}$, ${\boldsymbol{\mu}}_{\boldsymbol{en}}/\boldsymbol{\rho}$ and ${\boldsymbol{\mu}}_{\boldsymbol{tr}}/\boldsymbol{\rho}$ values. The data produced in this study were compared with theoretical photon attenuation data from the XMUDAT database and demonstrated good agreement. The results, which are based on a simple model geometry and pure elemental compositions, indicate that this approach can be applied to evaluate $\boldsymbol{\mu} /\boldsymbol{\rho}$, ${\boldsymbol{\mu}}_{\boldsymbol{en}}/\boldsymbol{\rho}$ and ${\boldsymbol{\mu}}_{\boldsymbol{tr}}/\boldsymbol{\rho}$ in a broad energy range for any element, compound or mixture.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotonsFemaleHumansComputer SimulationMonte Carlo Method

Autor:innen und Institutionen

  • Vocational School of Health Services, Medical Imaging Program, Akdeniz University, Antalya 07058, Turkey.
  • Informatics Institute, Division of Computational Science and Engineering, Istanbul Technical University, Istanbul 34469, Turkey.

Zitieren

APA

Sengul, A., & Bozkurt, A. (2024). Monte Carlo calculated photon interaction coefficients for several body tissues. Radiation Protection Dosimetry, 200(5), 487-495. https://doi.org/10.1093/rpd/ncae006

Vancouver

Sengul A, Bozkurt A. Monte Carlo calculated photon interaction coefficients for several body tissues. Radiation Protection Dosimetry. 2024;200(5):487-495. doi:10.1093/rpd/ncae006

BibTeX
@article{Sengul2024,
  author = {Sengul, Aycan and Bozkurt, Ahmet},
  title = {Monte Carlo calculated photon interaction coefficients for several body tissues},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  volume = {200},
  number = {5},
  pages = {487--495},
  doi = {10.1093/rpd/ncae006}
}