EUVIMEDEUVIMED entdecken
Crossref

Development of DynamicMC for PHITS Monte Carlo package

Hiroshi Watabe, Tatsuhiko Sato, Kwan Ngok Yu, Milena Zivkovic, Dragana Krstic, Dragoslav Nikezic, Kyeong Min Kim, Taiga Yamaya, Naoki Kawachi, Hiroki Tanaka, A K F Haque, M Rafiqul Islam und 1 weitere

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncad278 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Hiroshi Watabe und 12 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiation Protection and Safety Control, Cyclotron and Radioisotope Center, Tohoku University, 6-3 Aoba, Aramaki, Aoba-ku, Sendai, Miyagi…. Hauptthemen laut MEDLINE: Radiometry, Health Physics. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science, Ministry of Science, Technological development and Innovation of the Republic of Serbia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Previously, we have developed DynamicMC for modeling relative movement of Oak Ridge National Laboratory phantom in a radiation field for the Monte Carlo N-Particle package (Health Physics. 2023,124(4):301–309). Using this software, three-dimensional dose distributions in a phantom irradiated by a certain mono-energetic (Mono E) source can be deduced through its graphical user interface. In this study, we extended DynamicMC to be used in combination with the Particle and Heavy Ion Transport code System (PHITS) by providing it with a higher flexibility for dynamic movement for an anthropomorphic phantom. For this purpose, we implemented four new functions into the software, which are (1) to generate not only Mono E sources but also those having an energy spectrum of an arbitrary radioisotope (2) to calculate the absorbed doses for several radiologically important organs (3) to automatically average the calculated absorbed doses along the path of the phantom and (4) to generate user-defined slab shielding materials. The first and third items utilize the PHITS-specific modalities named radioisotope-source and sumtally functions, respectively. The computational cost and complexity can be dramatically reduced with these features. We anticipate that the present work and the developed open-source tools will be in the interest of nuclear radiation physics community for research and teaching purposes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiometryHealth PhysicsSoftwareMovementPhantoms, ImagingRadioisotopesMonte Carlo Method

Substanzen

Radioisotopes

Autor:innen und Institutionen

  • Division of Radiation Protection and Safety Control, Cyclotron and Radioisotope Center, Tohoku University, 6-3 Aoba, Aramaki, Aoba-ku, Sendai, Miyagi 980-8578, Japan.
  • Nuclear Science and Engineering Center, Japan Atomic Energy Agency, 2-4 Shirakata, Tokai, Ibaraki 319-1195, Japan.
  • Department of Physics, City University of Hong Kong, Tat Chee Avenue, Kowloon Tong, Hong Kong, China.
  • Faculty of Science, University of Kragujevac, R. Domanovica 12, 34000 Kragujevac, Serbia.
  • Department of Natural Sciences and Mathematics, State University of Novi Pazar, Vuka Karadzica 9, 36300 Novi Pazar, Serbia.
  • Korea Institute of Radiological & Medical Sciences, 75, Nowon-ro, Nowon-gu, Seoul 139-706, Korea.

Förderung

  • Japan Society for the Promotion of Science
  • Ministry of Science, Technological development and Innovation of the Republic of Serbia

Zitieren

APA

Watabe, H., Sato, T., Yu, K. N., Zivkovic, M., Krstic, D., Nikezic, D., Kim, K. M., Yamaya, T., Kawachi, N., Tanaka, H., Haque, A. K. F., Islam, M. R., & Shahmohammadi Beni, M. (2024). Development of DynamicMC for PHITS Monte Carlo package. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad278

Vancouver

Watabe H, Sato T, Yu KN, Zivkovic M, Krstic D, Nikezic D, et al. Development of DynamicMC for PHITS Monte Carlo package. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncad278

BibTeX
@article{Watabe2024,
  author = {Watabe, Hiroshi and Sato, Tatsuhiko and Yu, Kwan Ngok and Zivkovic, Milena and Krstic, Dragana and Nikezic, Dragoslav and Kim, Kyeong Min and Yamaya, Taiga and Kawachi, Naoki and Tanaka, Hiroki and Haque, A K F and Islam, M Rafiqul and Shahmohammadi Beni, Mehrdad},
  title = {Development of DynamicMC for PHITS Monte Carlo package},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncad278}
}
Kostenlos starten →