EUVIMEDEUVIMED entdecken
Crossref

Operator radiation exposure during radioembolisation of the liver: transfemoral versus transradial access using real-time dose monitoring

Federico Pedersoli iD, Jieming Fang, Edward Boas, John J Park iD

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncad236 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Federico Pedersoli und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Interventional Radiology, Department of Radiology, City of Hope, Comprehensive Cancer Center, Duarte, CA 91010, United States. Hauptthemen laut MEDLINE: Radiation Exposure, Embolization, Therapeutic. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, operator radiation exposure is compared utilising transradial access (TRA) versus transfemoral access (TFA) during transarterial radioembolisation (TARE) of liver tumors. Patients who underwent Y90 TARE between May 2017 and April 2018 were included. Electronic medical records and interventional data were collected and the following parameters evaluated: technical success, fluoroscopy time, operator radiation exposure and rate of operator radiation exposure per fluoroscopy time. Statistical analysis was performed with the Wilcoxon rank-sum test. A total of 22 patients (12 males, 10 females) underwent 22 procedures. A total of 12 procedures were performed via TFA and 10 via TRA. Technical success was 100% in both groups. Median fluoroscopy time (10 minutes for TRA vs 6.4 minutes for TFA, p = 0.082) was not statistically different. Both operator radiation exposure (49 vs 4.2 μSv, p = 0.00016) and rate of operator exposure (4.9 vs 0.71 μSv per min, p = 0.00021) were significantly higher in the TRA versus TFA groups, respectively.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ExposureEmbolization, TherapeuticMaleFemaleHumansRadial ArteryLiverFemoral ArteryTreatment OutcomeRetrospective Studies

Autor:innen und Institutionen

  • Division of Interventional Radiology, Department of Radiology, City of Hope, Comprehensive Cancer Center, Duarte, CA 91010, United States.

ORCID-Profile: Federico Pedersoli, John J Park

Zitieren

APA

Pedersoli, F., Fang, J., Boas, E., & Park, J. J. (2023). Operator radiation exposure during radioembolisation of the liver: transfemoral versus transradial access using real-time dose monitoring. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad236

Vancouver

Pedersoli F, Fang J, Boas E, Park JJ. Operator radiation exposure during radioembolisation of the liver: transfemoral versus transradial access using real-time dose monitoring. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad236

BibTeX
@article{Pedersoli2023,
  author = {Pedersoli, Federico and Fang, Jieming and Boas, Edward and Park, John J},
  title = {Operator radiation exposure during radioembolisation of the liver: transfemoral versus transradial access using real-time dose monitoring},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncad236}
}
Kostenlos starten →