Evaluation of institutional whole-body and extremity occupational radiation doses in nuclear medicine
Radiation Protection Dosimetry · 16.11.2023 · 199 (19) · 2318-2327
DOI: 10.1093/rpd/ncad235 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 25.08.2023. Verfasst von Yassine Bouchareb und 5 weiteren Autor:innen. Beteiligte Einrichtung: Sultan Qaboos University, College of Medicine and Health Sciences, Radiology and Molecular Imaging Department, PO Box 35, PC 123, Al-Khoud, Muscat, O…. Hauptthemen laut MEDLINE: Nuclear Medicine, Physicians, Occupational Exposure. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
This study evaluated nuclear medicine occupational radiation doses at Sultan Qaboos University Hospital, a 700-bed tertiary care teaching hospital in Oman. Personal effective whole-body doses, Hp(10), and extremity doses, Hp(0.07), were collected for 19 medical radiation workers over a 7-year period (2015–2021). Personal doses for four professional groups were measured using calibrated thermo-luminescence dosemeters ((LiF:Mg,Ti) TLD-100). The average, median and maximum cumulative doses were compared against the annual whole-body and extremity dose limits (20 mSv and 500 mSv y−1, respectively) and local dose investigation level (DIL; 6 mSv y−1). Personal whole-body doses (average:median:maximum) for technologists, medical physicists, nuclear medicine physicians and nurses were 1.8:1.1:7.8, 0.3:0.3:0.4, 0.1:0.1:0.2 and 0.1:0.1:0.2 mSv, respectively. Personal extremity doses for left and right hand (average and maximum doses) follow similar trends. Average annual effective whole-body and extremity doses were well below the recommended annual dose limits. The findings suggest lowering local DIL for all staff except for technologists.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Sultan Qaboos University, College of Medicine and Health Sciences, Radiology and Molecular Imaging Department, PO Box 35, PC 123, Al-Khoud, Muscat, Oman.
- Sultan Qaboos University Hospital, Radiology and Molecular Imaging Department, PO Box 38, PC 123, Al-Khoud, Muscat, Oman.
ORCID-Profile: Yassine Bouchareb
Zitieren
APA
Bouchareb, Y., Al-Mabsali, J., Al-Zeheimi, H., Al-Jabri, A., Tag, N., & Al-Dhuhli, H. (2023). Evaluation of institutional whole-body and extremity occupational radiation doses in nuclear medicine. Radiation Protection Dosimetry, 199(19), 2318-2327. https://doi.org/10.1093/rpd/ncad235
Vancouver
Bouchareb Y, Al-Mabsali J, Al-Zeheimi H, Al-Jabri A, Tag N, Al-Dhuhli H. Evaluation of institutional whole-body and extremity occupational radiation doses in nuclear medicine. Radiation Protection Dosimetry. 2023;199(19):2318-2327. doi:10.1093/rpd/ncad235
BibTeX
@article{Bouchareb2023,
author = {Bouchareb, Yassine and Al-Mabsali, Jihad and Al-Zeheimi, Hilal and Al-Jabri, Aziza and Tag, Naima and Al-Dhuhli, Humoud},
title = {Evaluation of institutional whole-body and extremity occupational radiation doses in nuclear medicine},
journal = {Radiation Protection Dosimetry},
year = {2023},
volume = {199},
number = {19},
pages = {2318--2327},
doi = {10.1093/rpd/ncad235}
}
EUVIMED