Calibration and simulation of a silicon dosemeter for ambient dose equivalent in low-earth orbit space
Radiation Protection Dosimetry · 2023
DOI: 10.1093/rpd/ncad226 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Sukwon Youn und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Bioengineering and Research Institute for Convergence Science, Graduate School of Convergence Science and Technology, Seoul Nat…. Hauptthemen laut MEDLINE: Radiation Monitoring, Silicon, Orbit, Cosmic Radiation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Research Foundation of Korea, Ministry of Science and ICT, Ministry of Education.
Abstract (Originalsprache)
A particle dosemeter (PD) is a payload of NEXTSat-2 in the low-earth orbit (LEO). The absorbed dose in LEO needs to be converted into the ambient dose equivalent (H*(10)). Due to a mixed field in LEO, the calibration factors (klow and khigh) should be determined for the low-and high-linear energy transfers (LET) (below and above 1.5 keV/μm), respectively. The PD was irradiated with a 137Cs source at the Korea Radiation Solution facility to obtain H*(10) and absorbed doses. However due to the lack of sources for the high-LET calibration, H*(10) and an absorbed dose were calculated by simulating PD for the high-energy neutron field at CERN-EU high-energy Reference Field. The measured klow of PD had a difference of 5.1% and 9.5% from the calculated value of PD and the measured value of Liulin detectors, respectively. However, a difference in khigh between PD and Liulin was explained by the contribution of non-neutron components to Liulin in the measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Applied Bioengineering and Research Institute for Convergence Science, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 08826, Korea.
- Space Science Division, Korea Astronomy and Space Science Institute, Daejeon 34055, Korea.
- Department of Radiological Science, Cheongju University, Cheongju 28503, Korea.
- Department of Physics, Kyungpook National University, Daegu 41566, Korea.
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA 91109, United States.
- Advanced Institute of Convergence Technology, Seoul National University, Suwon 16229, Korea.
ORCID-Profile: Sukwon Youn, Sung-Joon Ye
Förderung
- National Research Foundation of Korea
- Ministry of Science and ICT
- Ministry of Education
Zitieren
APA
Youn, S., Nam, U. W., Kim, S., Kim, H., Park, W. K., Sohn, J., Moon, B., Jun, I., & Ye, S. J. (2023). Calibration and simulation of a silicon dosemeter for ambient dose equivalent in low-earth orbit space. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad226
Vancouver
Youn S, Nam UW, Kim S, Kim H, Park WK, Sohn J, et al. Calibration and simulation of a silicon dosemeter for ambient dose equivalent in low-earth orbit space. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad226
BibTeX
@article{Youn2023,
author = {Youn, Sukwon and Nam, Uk-Won and Kim, Sunghwan and Kim, Hongjoo and Park, Won-Kee and Sohn, Jongdae and Moon, Bongkon and Jun, Insoo and Ye, Sung-Joon},
title = {Calibration and simulation of a silicon dosemeter for ambient dose equivalent in low-earth orbit space},
journal = {Radiation Protection Dosimetry},
year = {2023},
doi = {10.1093/rpd/ncad226}
}
EUVIMED