Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Maurício T Pazianotto und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, Aeronautics Institute of Technology, São José dos Campos, Brazil. Hauptthemen laut MEDLINE: Cosmic Radiation, Radiation Monitoring. Die Arbeit nennt 17 Literaturangaben. Gefördert von: FAPESP Projects.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cosmic-ray-induced particles at flight altitude present an increasing concern because of the development of aircraft with high maximum cruising altitude (higher than 40 000 ft) and because of the miniaturisation of and increase in the amount of embedded electronic systems. There are different codes used to estimate the radiation field through the atmosphere, using different approaches and Monte Carlo methods. This work aims to evaluate the influence on the neutron spectra at ground and flight altitude of the parameterizations employed to describe spallation reactions and the density profile of the atmosphere. The results show that different versions of Geant4 and the data driven models used significantly change the neutron fluence rate and the ambient dose equivalent rate. The results show that the different atmospheric density profiles considered do not significantly change the neutron spectra. In this work, we also present comparisons with onboard and ground level measurements.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cosmic RadiationRadiation MonitoringAltitudeRadiation DosageNeutronsAircraft

Autor:innen und Institutionen

  • Department of Physics, Aeronautics Institute of Technology, São José dos Campos, Brazil.
  • Nuclear Energy Division, Institute for Advanced Studies, São José dos Campos, Brazil.

ORCID-Profile: Maurício T Pazianotto

Förderung

  • FAPESP Projects

Zitieren

APA

Pazianotto, M. T., Federico, C. A., Gonçalez, O. L., & Carlson, B. V. (2023). Evaluation of the neutron spectrum at flight altitude with Geant4 using different parameterizations. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad039

Vancouver

Pazianotto MT, Federico CA, Gonçalez OL, Carlson BV. Evaluation of the neutron spectrum at flight altitude with Geant4 using different parameterizations. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad039

BibTeX
@article{Pazianotto2023,
  author = {Pazianotto, Maurício T and Federico, Claudio A and Gonçalez, Odair L and Carlson, Brett V},
  title = {Evaluation of the neutron spectrum at flight altitude with Geant4 using different parameterizations},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncad039}
}
Kostenlos starten →