EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A new detector concept based on the prompt gamma radiation analysis for In vivo boron monitoring in BNCT

M Silarski iD, K Dziedzic-Kocurek, F Sobczuk, A Nykiel, P Moskal, S Niedźwiecki, E Ł Stępień, M Szczepanek

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncac245 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von M Silarski und 7 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, PL-30-348 Krakow, Poland. Hauptthemen laut MEDLINE: Boron Neutron Capture Therapy. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education and Science, Polish National Centre for Research and Development, EU Horizon 2020 Research and Innovation Programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The problem of boron concentration monitoring during the boron neutron capture therapy (BNCT) therapy is one of the main challenges of this type of radiotherapy and is directly related to the nature of the interaction of neutrons with mater. Among the available in vivo methods of boron monitoring positron emission tomography seems to be very promising but it requires a new boron carrier with a β+ emitter, which is not yet clinically available. An alternative solution may be the prompt gamma radiation analysis (PGRA) based on the secondary radiation emitted in the interaction of neutrons with the patient’s tissues. This method requires, however, compact gamma radiation detection systems sustaining high counting rates and characterized by very good energy resolution. In this contribution, we present state-of-the-art solutions for monitoring in BNCT based on PGRA. Moreover, we describe a new concept of such a system based on position-sensitive scintillator detectors equipped with an anti-Compton shield and data analysis supported with modern artificial intelligence algorithms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Boron Neutron Capture TherapyHumansBoronGamma RaysArtificial IntelligenceNeutrons

Substanzen

Boron

Autor:innen und Institutionen

  • Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, PL-30-348 Krakow, Poland.
  • Institute of Nuclear Physics, Polish Academy of Sciences, PL-31-342 Krakow, Poland.
  • Center for Theranostics, Jagiellonian University, PL-31-501 Krakow, Poland.

ORCID-Profile: M Silarski

Förderung

  • Ministry of Education and Science
  • Polish National Centre for Research and Development
  • EU Horizon 2020 Research and Innovation Programme

Zitieren

APA

Silarski, M., Dziedzic-Kocurek, K., Sobczuk, F., Nykiel, A., Moskal, P., Niedźwiecki, S., Stępień, E. Ł., & Szczepanek, M. (2023). A new detector concept based on the prompt gamma radiation analysis for In vivo boron monitoring in BNCT. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncac245

Vancouver

Silarski M, Dziedzic-Kocurek K, Sobczuk F, Nykiel A, Moskal P, Niedźwiecki S, et al. A new detector concept based on the prompt gamma radiation analysis for In vivo boron monitoring in BNCT. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncac245

BibTeX
@article{Silarski2023,
  author = {Silarski, M and Dziedzic-Kocurek, K and Sobczuk, F and Nykiel, A and Moskal, P and Niedźwiecki, S and Stępień, E Ł and Szczepanek, M},
  title = {A new detector concept based on the prompt gamma radiation analysis for In vivo boron monitoring in BNCT},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncac245}
}
Kostenlos starten →