EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Real-world performance of a Food and Drug Administration–approved artificial intelligence tool for mammography in patients with prior breast surgery or indwelling biopsy clips

Emily B Ambinder iD, Colin Paulbeck, Shuchi Zinzuwadia, Lisa Mullen iD, Kelly S Myers iD, Eniola Oluyemi, Babita Panigrahi

Radiology Advances · 04.11.2026 · 3 (6)

DOI: 10.1093/radadv/umag042 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiology Advances, online erschienen am 10.10.2026. Verfasst von Emily B Ambinder und 6 weiteren Autor:innen. Beteiligte Einrichtung: Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD 21287, United States. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Artificial intelligence (AI) tools are increasingly used in clinical screening mammography, but their performance in patients with prior breast surgery or indwelling biopsy clips, who represent a substantial proportion of screening populations, has not been well characterized.

Purpose

To evaluate the real-world performance of an Food and Drug Administration–approved AI mammography tool in patients with prior breast surgery or biopsy clips. Methods and Materials We retrospectively reviewed all screening mammograms performed at our institution between August 1, 2024, and February 28, 2025, after implementation of a commercially available AI tool (Transpara 1.7.4-A), merging clinical outcomes with the AI risk score (low, intermediate, or elevated). Patients were stratified by procedural history into 3 groups: prior breast surgery, biopsy clip, and reference (ie, neither intervention). Sensitivity, positive predictive value (PPV), and false positive rate (FPR) at the elevated and intermediate + elevated thresholds were compared using Fisher exact tests presented as percentage (95% confidence interval [CI]).

Results

A total of 24 427 screening mammograms were included (mean age 61 ± 13 years): 19 287 in the reference group, 2647 in the surgery group, and 2493 in the biopsy clip group. AI sensitivity at the intermediate + elevated threshold was preserved (reference 92.1% [95% CI, 86.9%-95.3%], surgery 90.5% [95% CI, 71.1%-97.3%], biopsy clip 90.0% [95% CI, 69.9%-97.2%]; both P > .6). The AI-PPV of an elevated exam was correspondingly reduced in altered-breast patients (reference 13.6% [95% CI, 11.1%-16.6%], surgery 5.5% [95% CI, 2.9%-10.0%], biopsy clip 4.9% [95% CI, 2.5%-9.4%]; both P < .005 vs reference). The AI-FPR was higher in both subgroups at the intermediate + elevated threshold (reference 35.6% [95% CI, 34.9%-36.3%] vs surgery 47.9% [95% CI, 46.0%-49.9%] and biopsy clip 47.9% [95% CI, 45.9%-49.8%]; both P < .001) and more than doubled at the elevated threshold (reference 2.7% [95% CI, 2.5%-2.9%] vs surgery 5.9% [95% CI, 5.1%-6.9%] and biopsy clip 6.2% [95% CI, 5.3%-7.2%]; both P < .001).

Conclusion

AI examination–level sensitivity for breast cancer was preserved in patients with prior breast surgery or indwelling biopsy clips. However, an elevated AI risk score was less likely to reflect a cancer in these patients than in the reference group, with a lower AI-PPV and higher AI-FPR.

Schlagwörter

Stichwörter der Autor:innen

artificial intelligencebiopsy clipbreast cancerbreast malignancypostsurgical breastscreening mammography

Autor:innen und Institutionen

  • Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD 21287, United States.

ORCID-Profile: Emily B Ambinder, Lisa Mullen, Kelly S Myers

Zitieren

APA

Ambinder, E. B., Paulbeck, C., Zinzuwadia, S., Mullen, L., Myers, K. S., Oluyemi, E., & Panigrahi, B. (2026). Real-world performance of a Food and Drug Administration–approved artificial intelligence tool for mammography in patients with prior breast surgery or indwelling biopsy clips. Radiology Advances, 3(6). https://doi.org/10.1093/radadv/umag042

Vancouver

Ambinder EB, Paulbeck C, Zinzuwadia S, Mullen L, Myers KS, Oluyemi E, et al. Real-world performance of a Food and Drug Administration–approved artificial intelligence tool for mammography in patients with prior breast surgery or indwelling biopsy clips. Radiology Advances. 2026;3(6). doi:10.1093/radadv/umag042

BibTeX
@article{Ambinder2026,
  author = {Ambinder, Emily B and Paulbeck, Colin and Zinzuwadia, Shuchi and Mullen, Lisa and Myers, Kelly S and Oluyemi, Eniola and Panigrahi, Babita},
  title = {Real-world performance of a Food and Drug Administration–approved artificial intelligence tool for mammography in patients with prior breast surgery or indwelling biopsy clips},
  journal = {Radiology Advances},
  year = {2026},
  volume = {3},
  number = {6},
  doi = {10.1093/radadv/umag042}
}
Kostenlos starten →