EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Deep learning MRI halves scan time and preserves image quality across routine neuroradiologic examinations

Shawn K Lyo iD, Suyash Mohan iD, Michael J Hoch iD, Vivek P Patel iD, Robert M Kurtz iD, Alvand Hassankhani iD

Radiology Advances · 04.09.2025 · 2 (5)

DOI: 10.1093/radadv/umaf029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiology Advances, online erschienen am 23.08.2025. Verfasst von Shawn K Lyo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, United States. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnetic resonance imaging (MRI) is a cornerstone of neuroimaging but is limited by lengthy acquisition times, which can lead to motion artifacts, patient discomfort, and delayed care. Deep learning reconstruction is an emerging technology that can offer image acquisition acceleration while maintaining image quality.

Purpose

To compare image quality and acquisition efficiency between deep learning–accelerated vs conventional MRI (C-MRI) across a spectrum of routine neuroradiologic examinations. Materials and Methods In this single-center retrospective study, 26 patients underwent imaging with a commercially available, FDA-cleared deep learning-accelerated MRI reconstruction algorithm (Deep Resolve, Siemens Healthineers), and C-MRI on a Siemens 3 T MAGNETOM Vida scanner between October 24 and November 14, 2023. A total of 113 sequence pairs were acquired across multiple body parts (brain [n = 28], cervical spine [n = 24], thoracic spine [n = 16], lumbar spine [n = 14], internal auditory canals [n = 5], sella [n = 5], neck [n = 5], temporomandibular joints [n = 6], brachial plexus [n = 4], and orbits [n = 6]) and sequences (T2 [n = 38], T1 [n = 30], short tau inversion recovery [n = 21], T1 post-contrast [n = 17], T2 fluid attenuated inversion recovery [n = 5], and proton density [n = 2]) and evaluated by 4 neuroradiologists blinded to the acquisition method for image quality using a 5-point Likert scale. Acquisition parameters were extracted from Digital Imaging and Communications in Medicine (DICOM) metadata and statistically compared. Rater preferences and interrater reliability were assessed using nonparametric tests and intraclass correlation coefficients.

Results

Deep learning reduced mean scan time by 51.6% (95% CI: 45.7%–57.7%; from 110.8 seconds to 53.7 seconds; P < .001). Image quality assessments using a Likert scale showed scores slightly above neutral for signal-to-noise ratio (mean 3.51; 95% CI: 3.44–3.58), structural delineation (mean 3.51, 95% CI: 3.44–3.56), and overall image quality (mean 3.56, 95% CI: 3.49–3.63). However, poor interrater reliability (intraclass correlation [ICC] range: 0.06–0.33) showed that the observed differences were not consistent, indicating functional equivalence between conventional and deep learning images.

Conclusion

Deep learning MRI enabled substantial scan time reductions while maintaining image quality.

Schlagwörter

Stichwörter der Autor:innen

MRIMRI reconstructiondeep learning MRIdeep learning MRI reconstructionhybrid imaging protocolsimage qualityneuroradiologyscan time reduction

Autor:innen und Institutionen

  • Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA 19104, United States.
  • Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, PA 19107, United States.

ORCID-Profile: Shawn K Lyo, Suyash Mohan, Michael J Hoch, Vivek P Patel, Robert M Kurtz, Alvand Hassankhani

Zitieren

APA

Lyo, S. K., Mohan, S., Hoch, M. J., Patel, V. P., Kurtz, R. M., & Hassankhani, A. (2025). Deep learning MRI halves scan time and preserves image quality across routine neuroradiologic examinations. Radiology Advances, 2(5). https://doi.org/10.1093/radadv/umaf029

Vancouver

Lyo SK, Mohan S, Hoch MJ, Patel VP, Kurtz RM, Hassankhani A. Deep learning MRI halves scan time and preserves image quality across routine neuroradiologic examinations. Radiology Advances. 2025;2(5). doi:10.1093/radadv/umaf029

BibTeX
@article{Lyo2025,
  author = {Lyo, Shawn K and Mohan, Suyash and Hoch, Michael J and Patel, Vivek P and Kurtz, Robert M and Hassankhani, Alvand},
  title = {Deep learning MRI halves scan time and preserves image quality across routine neuroradiologic examinations},
  journal = {Radiology Advances},
  year = {2025},
  volume = {2},
  number = {5},
  doi = {10.1093/radadv/umaf029}
}
Kostenlos starten →