EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Implementation of a gait and balance battery of outcome measures in an inpatient rehabilitation hospital

Leah Ling iD, Randy Carson, Geneviève N Olivier, Margaret A French iD

Physical Therapy · 02.07.2026 · 106 (7)

DOI: 10.1093/ptj/pzag059 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical Therapy, online erschienen am 29.05.2026. Verfasst von Leah Ling und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT 84108, United States. Hauptthemen laut MEDLINE: Postural Balance, Outcome Assessment, Health Care, Brain Injuries, Spinal Cord Injuries. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Importance Standardized outcome measure batteries are important for tracking functional progress, enhancing communication among providers, and evaluating intervention effectiveness in physical therapy. However, implementation of standardized batteries is challenging due to time constraints, documentation requirements, and limited resources.

Objective

The objective was to evaluate the implementation of a standardized gait and balance outcome measure battery by physical therapists for patients with stroke, brain injury, and spinal cord injury in the inpatient rehabilitation facility (IRF) setting.

Design

This study used a retrospective cohort study of 773 episodes of care at the IRF, and a quantitative survey for 22 staff physical therapists at the IRF.

Setting

This study was conducted at a 50-bed IRF in the United States.

Interventions

A standardized outcome measure battery with 5 measures (10 Meter Walk Test, 6 Minute Walk Test, Berg Balance Scale, Functional Gait Assessment, and 5 Times Sit to Stand) was implemented by all physical therapist teams at the IRF. Main Outcomes and Measures The main implementation outcomes were Penetration and Sustainability, assessed with retrospective cohort data, and Acceptability and Feasibility, assessed with the quantitative survey of physical therapists.

Results

There was a significant improvement in the completion rates of all 5 outcome measures, with most measures exceeding a 70% completion rate threshold 1 year after implementation. Completion rates of the entire battery did not reach 70%. Physical therapists indicated that implementation of the battery resulted in positive practice changes, and that barriers to completion were patients’ functional levels and the time required for completion.

Conclusions

Implementation of a standardized outcome measure battery is feasible in the IRF setting. However, outcome measure completion rates may improve with a more condensed battery and with integration into clinical workflows. Relevance This study provides a practical model for IRFs to adopt and evaluate standardized outcome measure batteries that improve physical therapists’ ability to assess physical function across health systems and settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Postural BalanceOutcome Assessment, Health CareBrain InjuriesSpinal Cord InjuriesGaitHumansRetrospective StudiesMaleFemaleStroke RehabilitationHospitals, RehabilitationMiddle AgedInpatientsAdultPhysical Therapy Modalities

Stichwörter der Autor:innen

Outcome assessment (health care)brain injuriesmobilityspinal cord injuriesstroke

Autor:innen und Institutionen

  • Department of Physical Therapy and Athletic Training, University of Utah, Salt Lake City, UT 84108, United States.
  • Department of Physical Medicine and Rehabilitation, Craig H. Neilsen Rehabilitation Hospital, University of Utah Health, Salt Lake City, UT 84132, United States.

ORCID-Profile: Leah Ling, Margaret A French

Zitieren

APA

Ling, L., Carson, R., Olivier, G. N., & French, M. A. (2026). Implementation of a gait and balance battery of outcome measures in an inpatient rehabilitation hospital. Physical Therapy, 106(7). https://doi.org/10.1093/ptj/pzag059

Vancouver

Ling L, Carson R, Olivier GN, French MA. Implementation of a gait and balance battery of outcome measures in an inpatient rehabilitation hospital. Physical Therapy. 2026;106(7). doi:10.1093/ptj/pzag059

BibTeX
@article{Ling2026,
  author = {Ling, Leah and Carson, Randy and Olivier, Geneviève N and French, Margaret A},
  title = {Implementation of a gait and balance battery of outcome measures in an inpatient rehabilitation hospital},
  journal = {Physical Therapy},
  year = {2026},
  volume = {106},
  number = {7},
  doi = {10.1093/ptj/pzag059}
}
Kostenlos starten →