EUVIMEDEUVIMED entdecken
Open Access

Computerized Adaptive Testing for the Berg Balance Scale Improves Measurement Efficiency Without Compromising Precision in People With Stroke

Bryant A Seamon iD, Steven A Kautz, Craig A Velozo

Physical Therapy · 01.11.2024 · 104 (11)

DOI: 10.1093/ptj/pzae112 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physical Therapy, online erschienen am 08.08.2024. Verfasst von Bryant A Seamon und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ralph H. Johnson VA Medical Center, Charleston, South Carolina, USA. Hauptthemen laut MEDLINE: Postural Balance, Disability Evaluation, Stroke Rehabilitation. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 68 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NIH National Institute of Neurological Disorders and Stroke, VA/ORD Rehabilitation R&D Service.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The objectives of this study were to confirm the Berg Balance Scale’s (BBS) measurement properties and unidimensionality with an item response theory analysis in persons with subacute and chronic stroke and to examine the precision and efficiency of computerized adaptive testing (CAT).

Methods

Data were obtained from 519 ambulatory persons with subacute and chronic stroke in 2 retrospective databases. A principal component analysis (PCA) of residuals was used to evaluate unidimensionality. BBS fit to a rating scale model versus a partial credit model was examined, and item parameters were generated for CAT calibration. Person measures from all 14 items were defined as actual balance ability. BBS CAT simulations were used to examine changes in measurement precision with increasing number of items administered and a precision-based stopping rule (0.5 logit standard error [SE] threshold).

Results

A PCA of residuals supports the BBS unidimensionality and Rasch analysis supports using the rating scale model for measurement. Maximum precision for BBS CAT was SE = 0.40 logits when administering all items. BBS CAT estimated balance ability was highly correlated with actual ability when 4 or more items were administered (r > 0.9). Precision was within 0.5 logits when 5 or more items were administered (SE < 0.48 logits). BBS CAT estimated balance ability was highly correlated with actual ability (r = 0.952) using a precision-based stopping rule. The average number of items administered with the precision-based stopping rule was 5.43.

Conclusion

The BBS is sufficiently unidimensional, and the rating scale model can be used for measurement. BBS CAT is efficient and replicates the full instrument’s reliability when measuring balance ability in ambulatory persons with subacute and chronic stroke. Future work should aim to enhance the interpretability of measures to facilitate clinical decision-making. Impact BBS CAT provides an efficient way of measuring balance ability for individuals in stroke rehabilitation giving clinicians more time with patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Postural BalanceDisability EvaluationStroke RehabilitationHumansFemaleMaleMiddle AgedAgedRetrospective StudiesStrokePsychometricsReproducibility of ResultsPrincipal Component Analysis

Stichwörter der Autor:innen

BalanceMeasurement – AppliedStroke

Autor:innen und Institutionen

  • Ralph H. Johnson VA Medical Center, Charleston, South Carolina, USA.
  • Division of Physical Therapy, Department of Rehabilitation Sciences, College of Health Professions, Medical University of South Carolina, Charleston, South Carolina, USA.
  • Department of Health Sciences and Research, College of Health Professions, Medical University of South Carolina, Charleston, South Carolina, USA.
  • Division of Occupational Therapy, Department of Rehabilitation Sciences, College of Health Professions, Medical University of South Carolina, Charleston, South Carolina, USA.

ORCID-Profile: Bryant A Seamon

Förderung

  • NIH HHS
  • NIH National Institute of Neurological Disorders and Stroke
  • VA/ORD Rehabilitation R&D Service
  • VA Office of Research and Development
  • NIH Center of Biomedical Research Excellence in Stroke Recovery
  • NIGMS NIH HHS
  • Promotion of Doctoral Studies Level I Scholarship from the Foundation for Physical Therapy Research
  • NINDS NIH HHS

Zitieren

APA

Seamon, B. A., Kautz, S. A., & Velozo, C. A. (2024). Computerized Adaptive Testing for the Berg Balance Scale Improves Measurement Efficiency Without Compromising Precision in People With Stroke. Physical Therapy, 104(11). https://doi.org/10.1093/ptj/pzae112

Vancouver

Seamon BA, Kautz SA, Velozo CA. Computerized Adaptive Testing for the Berg Balance Scale Improves Measurement Efficiency Without Compromising Precision in People With Stroke. Physical Therapy. 2024;104(11). doi:10.1093/ptj/pzae112

BibTeX
@article{Seamon2024,
  author = {Seamon, Bryant A and Kautz, Steven A and Velozo, Craig A},
  title = {Computerized Adaptive Testing for the Berg Balance Scale Improves Measurement Efficiency Without Compromising Precision in People With Stroke},
  journal = {Physical Therapy},
  year = {2024},
  volume = {104},
  number = {11},
  doi = {10.1093/ptj/pzae112}
}
Kostenlos starten →