Identification and removal of system-induced autofluorescence in miniaturized fiber-optic fluorescence endoscopes
PNAS Nexus · 31.07.2025 · 4 (8)
DOI: 10.1093/pnasnexus/pgaf226 ↗Kurz gefasst
Fachartikel in der Zeitschrift PNAS Nexus, online erschienen am 23.07.2025. Verfasst von Lei Xiang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, SA 5005, Australia. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Health and Medical Research Council, Heart Foundation Future Leader Fellowship, Hospital Research Foundation Project.
Abstract (Originalsprache)
Miniaturized fiber-optic fluorescence endoscopes play a crucial role in medical diagnostics and research, but system-induced autofluorescence remains a significant challenge, particularly in single-fiber setups. While recent advances, such as double-clad fiber (DCF) and DCF couplers, have reduced background noise, complete elimination remains challenging. Research on the various sources of system-induced autofluorescence and the methods to remove them is scarce. This study seeks to fulfill this need by proposing practical approaches to the removal of system-induced autofluorescence. This study presents the methods to suppress static background noise and proposes an algorithm based on least-squares linear spectral unmixing to remove variable system-induced autofluorescence artifacts. The algorithm was evaluated on a single-fiber DCF intravascular imaging system, with phantom and rodent in vivo experiments confirming its effectiveness. Results showed accurate differentiation between true sample fluorescence and system-induced autofluorescence artifacts through the validation with optical coherence tomography images and histology results, further verified by statistical analysis. Unlike simple background subtraction, the method addresses both background noise and incidental artifacts, providing robust performance under varying conditions. Our method may be adapted to various fiber-based endoscopy setups and be compatible with different fluorescent agents and autofluorescence imaging, broadening its applicability in biomedical imaging.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, SA 5005, Australia.
- Institute for Photonics and Advanced Sensing, University of Adelaide, Adelaide, SA 5005, Australia.
- Lifelong Health Theme, South Australian Health and Medical Research Institute (SAHMRI), Adelaide, SA 5000, Australia.
- Faculty of Health and Medical Sciences, University of Adelaide, Adelaide, SA 5005, Australia.
ORCID-Profile: Lei Xiang, Joanne Tsui Ming Tan, Christina A Bursill, Robert A McLaughlin, Jiawen Li
Förderung
- National Health and Medical Research Council
- Heart Foundation Future Leader Fellowship
- Hospital Research Foundation Project
- Lin Huddleston Heart Foundation Fellowship
Zitieren
APA
Xiang, L., Chen, R., Tan, J. T. M., Nankivell, V., Bursill, C. A., McLaughlin, R. A., & Li, J. (2025). Identification and removal of system-induced autofluorescence in miniaturized fiber-optic fluorescence endoscopes. PNAS Nexus, 4(8). https://doi.org/10.1093/pnasnexus/pgaf226
Vancouver
Xiang L, Chen R, Tan JTM, Nankivell V, Bursill CA, McLaughlin RA, et al. Identification and removal of system-induced autofluorescence in miniaturized fiber-optic fluorescence endoscopes. PNAS Nexus. 2025;4(8). doi:10.1093/pnasnexus/pgaf226
BibTeX
@article{Xiang2025,
author = {Xiang, Lei and Chen, Rouyan and Tan, Joanne Tsui Ming and Nankivell, Victoria and Bursill, Christina A and McLaughlin, Robert A and Li, Jiawen},
title = {Identification and removal of system-induced autofluorescence in miniaturized fiber-optic fluorescence endoscopes},
journal = {PNAS Nexus},
year = {2025},
volume = {4},
number = {8},
doi = {10.1093/pnasnexus/pgaf226}
}