Fachartikel in der Zeitschrift Pain Medicine, 2025. Verfasst von Peter D Vu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Medicine and Rehabilitation, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX 77…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Spinal Cord Stimulation, Pain Management, Transcutaneous Electric Nerve Stimulation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Magnetic resonance imaging (MRI) safety with implanted neuromodulation devices presents a critical challenge in modern medicine. While spinal cord stimulation (SCS) and peripheral nerve stimulation (PNS) devices are increasingly utilized for pain management, the scattered nature of manufacturer-specific MRI safety information creates substantial challenges for healthcare providers in making informed clinical decisions. Furthermore, despite the public availability of this information, a comprehensive review of the literature reveals no centralized repository of data regarding SCS and PNS.

Objective

To synthesize comprehensive MRI safety data from multiple manufacturers of SCS and PNS devices into a centralized resource for clinicians, thereby streamlining the decision-making process for MRI scanning in patients with implanted neuromodulation devices.

Methods

We collected MRI safety data for devices from 10 major neurostimulation companies (Abbott, Biotronik, Boston Scientific, Curonix, Mainstay, Medtronic, Nalu, Nevro, Saluda, and SPR Therapeutics) through December 2024. Data collection involved direct communication with manufacturers and analysis of technical documentation to extract specific MRI-related parameters.

Results

Full-body MRI safety at 1.5 T is standard across most SCS systems, with select devices permitting 3.0 T imaging. Specific limitations vary by manufacturer, including restrictions on spatial gradient magnetic fields (1000–4000 Gauss/cm), specific absorption rates, and active scan times (15–60 minutes). PNS systems show similar safety patterns.

Conclusions

This manuscript addresses the urgent need for centralized safety information. As device technology continues to evolve, this resource will require ongoing updates to maintain its utility in supporting informed clinical decision making and patient care.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingSpinal Cord StimulationPain ManagementTranscutaneous Electric Nerve StimulationHumansPeripheral NervesImplantable Neurostimulators

Stichwörter der Autor:innen

MRI safetyneuromodulationperipheral nerve stimulationspinal cord stimulation

Autor:innen und Institutionen

  • Department of Physical Medicine and Rehabilitation, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX 77030, United States.
  • Department of Physical Medicine and Rehabilitation, Burke Rehabilitation Hospital, White Plains, NY 10605, United States.
  • Department of Physical Medicine and Rehabilitation, Providence St Luke's Rehabilitation Medical Center, Spokane, WA 99202, United States.
  • Department of Anesthesiology, Perioperative, and Pain Medicine, Harvard Medical School, Brigham and Women's Hospital, Boston, MA 02115, United States.
  • Division of Anesthesiology, Critical Care & Pain Medicine, Department of Pain Medicine, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, United States.

ORCID-Profile: Peter D Vu, Robert J Yong, Christopher L Robinson, Matthew Chung

Zitieren

APA

Vu, P. D., Slitzky, M., Miller, K., Yong, R. J., Robinson, C. L., & Chung, M. (2025). Provision of up-to-date magnetic resonance imaging conditionality for current peripheral nerve stimulation and spinal cord stimulation systems in pain management. Pain Medicine. https://doi.org/10.1093/pm/pnaf076

Vancouver

Vu PD, Slitzky M, Miller K, Yong RJ, Robinson CL, Chung M. Provision of up-to-date magnetic resonance imaging conditionality for current peripheral nerve stimulation and spinal cord stimulation systems in pain management. Pain Medicine. 2025. doi:10.1093/pm/pnaf076

BibTeX
@article{Vu2025,
  author = {Vu, Peter D and Slitzky, Matthew and Miller, Kobe and Yong, Robert J and Robinson, Christopher L and Chung, Matthew},
  title = {Provision of up-to-date magnetic resonance imaging conditionality for current peripheral nerve stimulation and spinal cord stimulation systems in pain management},
  journal = {Pain Medicine},
  year = {2025},
  doi = {10.1093/pm/pnaf076}
}
Kostenlos starten →