EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In vivo X-ray microtomography locally affects stem radial growth with no immediate physiological impact

Laura Mekarni iD, Hervé Cochard iD, Marco M Lehmann iD, Pascal Turberg iD, Charlotte Grossiord iD

Plant Physiology · 2024

DOI: 10.1093/plphys/kiae285 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Plant Physiology, 2024. Verfasst von Laura Mekarni und 4 weiteren Autor:innen. Beteiligte Einrichtung: Plant Ecology Research Laboratory PERL, School of Architecture, Civil and Environmental Engineering, EPFL, CH-1015 Lausanne, Switzerland. Hauptthemen laut MEDLINE: X-Ray Microtomography, Plant Stems, Quercus, Acer. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swiss National Science Foundation, Sandoz Family Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microcomputed tomography (µCT) is a nondestructive X-ray imaging method used in plant physiology to visualize in situ plant tissues that enables assessments of embolized xylem vessels. Whereas evidence for X-ray-induced cellular damage has been reported, the impact on plant physiological processes such as carbon (C) uptake, transport, and use is unknown. Yet, these damages could be particularly relevant for studies that track embolism and C fluxes over time. We examined the physiological consequences of µCT scanning for xylem embolism over 3 mo by monitoring net photosynthesis (Anet), diameter growth, chlorophyll (Chl) concentration, and foliar nonstructural carbohydrate (NSC) content in 4 deciduous tree species: hedge maple (Acer campestre), ash (Fraxinus excelsior), European hornbeam (Carpinus betulus), and sessile oak (Quercus petraea). C transport from the canopy to the roots was also assessed through 13C labeling. Our results show that monthly X-ray application did not impact foliar Anet, Chl, NSC content, and C transport. Although X-ray effects did not vary between species, the most pronounced impact was observed in sessile oak, marked by stopped growth and stem deformations around the irradiated area. The absence of adverse impacts on plant physiology for all the tested treatments indicates that laboratory-based µCT systems can be used with different beam energy levels and doses without threatening the integrity of plant physiology within the range of tested parameters. However, the impacts of repetitive µCT on the stem radial growth at the irradiated zone leading to deformations in sessile oak might have lasting implications for studies tracking plant embolism in the longer-term.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

X-Ray MicrotomographyPlant StemsQuercusAcerPlant LeavesPhotosynthesisXylemCarbonChlorophyllFraxinusPlant RootsTreesBiological TransportBetulaceae

Substanzen

CarbonChlorophyll

Autor:innen und Institutionen

  • Plant Ecology Research Laboratory PERL, School of Architecture, Civil and Environmental Engineering, EPFL, CH-1015 Lausanne, Switzerland.
  • Swiss Federal Institute for Forest, Snow and Landscape Research WSL, Community Ecology Unit, 8903 Birmensdorf, Switzerland.
  • Université Clermont Auvergne, INRAE, PIAF, 63000 Clermont-Ferrand, France.

ORCID-Profile: Laura Mekarni, Hervé Cochard, Marco M Lehmann, Pascal Turberg, Charlotte Grossiord

Förderung

  • Swiss National Science Foundation
  • Sandoz Family Foundation

Zitieren

APA

Mekarni, L., Cochard, H., Lehmann, M. M., Turberg, P., & Grossiord, C. (2024). In vivo X-ray microtomography locally affects stem radial growth with no immediate physiological impact. Plant Physiology. https://doi.org/10.1093/plphys/kiae285

Vancouver

Mekarni L, Cochard H, Lehmann MM, Turberg P, Grossiord C. In vivo X-ray microtomography locally affects stem radial growth with no immediate physiological impact. Plant Physiology. 2024. doi:10.1093/plphys/kiae285

BibTeX
@article{Mekarni2024,
  author = {Mekarni, Laura and Cochard, Hervé and Lehmann, Marco M and Turberg, Pascal and Grossiord, Charlotte},
  title = {In vivo X-ray microtomography locally affects stem radial growth with no immediate physiological impact},
  journal = {Plant Physiology},
  year = {2024},
  doi = {10.1093/plphys/kiae285}
}
Kostenlos starten →