Diagnostic Performance of Nanopore-targeted Sequencing for Sputum Smear-negative Pulmonary Tuberculosis: A Retrospective Study
Open Forum Infectious Diseases · 02.06.2026 · 13 (6)
DOI: 10.1093/ofid/ofag323 ↗Kurz gefasst
Fachartikel in der Zeitschrift Open Forum Infectious Diseases, online erschienen am 26.05.2026. Verfasst von Wei Wei und 4 weiteren Autor:innen. Beteiligte Einrichtung: Clinic and Research Centre of Tuberculosis, Shanghai Key Laboratory of Tuberculosis, Shanghai Pulmonary Hospital, School of Medicine, Tongji Universi…. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To evaluate the diagnostic performance of nanopore-targeted sequencing (NTS) for sputum smear-negative pulmonary tuberculosis (PTB).
Methods
In this retrospective study, bronchoalveolar lavage fluid from patients with suspected PTB and negative sputum smears was tested with NTS, Xpert MTB/RIF, and MGIT 960 culture at Shanghai Pulmonary Hospital (August 2022–March 2024). Sensitivity and specificity were evaluated against both microbiological and composite reference standards. Receiver operating characteristic curves were generated and Youden's index was employed to determine the optimal NTS cutoff.
Results
Among the 249 participants enrolled, 100 were microbiologically confirmed PTB, 33 were probable PTB, and 116 were tuberculosis-negative. Under microbiological reference standard, the sensitivity of NTS was 0.940 (95% confidence interval [CI], 0.869–0.975), higher than Xpert MTB/RIF (0.840 [95% CI, 0.750–0.903]; P = .041) and MGIT 960 culture (0.640 [95% CI, 0.537–0.732]; both P < .001). The specificity of NTS was 0.776 (95% CI 0.687–0.846), compared to 0.974 (95% CI 0.921–0.993) for Xpert MTB/RIF and 1.000 (95% CI 0.960–1.000) for MGIT 960 culture. Excluding patients with prior PTB history, NTS specificity increased to 0.856 (95% CI, 0.766–0.916). According to Youden's index, when 4 Mycobacterium tuberculosis–specific sequence reads was defined as the optimal NTS cutoff for positive NTS result, the specificity of NTS rose to 0.907 (95% CI, 0.827–0.954).
Conclusions
NTS offers rapid, highly sensitive detection of PTB in patients with low bacillary burden. Applying an optimal read-count cutoff and accounting for prior PTB history can enhance clinical utility.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Clinic and Research Centre of Tuberculosis, Shanghai Key Laboratory of Tuberculosis, Shanghai Pulmonary Hospital, School of Medicine, Tongji University, Shanghai, China.
- Division of Infectious Diseases, Department of Medicine, Karolinska Institute, Stockholm, Sweden.
- Department of Infectious Diseases, Karolinska University Hospital, Stockholm, Sweden.
Zitieren
APA
Wei, W., Zheng, X., Yao, L., Sun, Q., & Sha, W. (2026). Diagnostic Performance of Nanopore-targeted Sequencing for Sputum Smear-negative Pulmonary Tuberculosis: A Retrospective Study. Open Forum Infectious Diseases, 13(6). https://doi.org/10.1093/ofid/ofag323
Vancouver
Wei W, Zheng X, Yao L, Sun Q, Sha W. Diagnostic Performance of Nanopore-targeted Sequencing for Sputum Smear-negative Pulmonary Tuberculosis: A Retrospective Study. Open Forum Infectious Diseases. 2026;13(6). doi:10.1093/ofid/ofag323
BibTeX
@article{Wei2026,
author = {Wei, Wei and Zheng, Xubin and Yao, Lan and Sun, Qin and Sha, Wei},
title = {Diagnostic Performance of Nanopore-targeted Sequencing for Sputum Smear-negative Pulmonary Tuberculosis: A Retrospective Study},
journal = {Open Forum Infectious Diseases},
year = {2026},
volume = {13},
number = {6},
doi = {10.1093/ofid/ofag323}
}
EUVIMED