Diagnostic Accuracy of Lung and Abdominal Ultrasound for Tuberculosis in a German Multicenter Cohort of Patients With Presumed Tuberculosis Disease
Open Forum Infectious Diseases · 27.11.2024 · 11 (12)
DOI: 10.1093/ofid/ofae651 ↗Kurz gefasst
Fachartikel in der Zeitschrift Open Forum Infectious Diseases, online erschienen am 09.12.2024. Verfasst von Stefan Fabian Weber und 20 weiteren Autor:innen. Beteiligte Einrichtung: Department for Infectious Disease and Tropical Medicine, University Hospital Heidelberg, Heidelberg, Germany. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DZIF, Center for Infectious Disease Research.
Abstract (Originalsprache)
Background
There is limited evidence on point-of-care ultrasound for tuberculosis (TB), but studies suggest high sensitivity, especially for lung ultrasound (LUS). However, insufficient data are available on specificity of the examination and its generalizability to a broader patient population.
Aims
Our study aimed to establish accuracy for lung, chest, and abdominal ultrasound, individually and in combination, for TB diagnosis.
Methods
We conducted a prospective diagnostic accuracy study among consecutive adult out- and inpatients with probable TB in three German referral hospitals. We applied a comprehensive standardized ultrasound protocol. TB diagnosis was established by a microbiological reference standard including polymerase chain reaction and culture.
Results
A total of 102 participants originating from 30 different countries were enrolled. HIV prevalence was 7/99 (7%) and 73/102 (72%) had confirmed TB. TB was limited to the lungs in 15/34 (44%) of refugees and 27/39 (69%) in nonrefugees. Focused assessment with sonography for HIV-associated tuberculosis had a sensitivity of 40% (95% confidence interval [CI], 30–52) and specificity of 55% (95% CI, 38–72). Additional findings, such as small subpleural consolidations on LUS had a high sensitivity (88%; 95% CI, 78–93), but a low specificity (17%; 95% CI, 8–35). Larger consolidations in the lung apices had a sensitivity of 19% (95% CI, 12–30) and a specificity of 97% (95% CI, 83–100).
Conclusions
Our study establishes the first data on LUS performance against a comprehensive reference standard. Overall, our data suggest that ultrasound does not meet the requirements for triage but previously described and novel ultrasound targets in combination could aid in the clinical decision making. Registry: DRKS00026636
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department for Infectious Disease and Tropical Medicine, University Hospital Heidelberg, Heidelberg, Germany.
- Department for Parasitology, University Hospital Heidelberg, Heidelberg, Germany.
- German Center for Infectious Disease Research, DZIF Partner Site Heidelberg, Heidelberg, Germany.
- Department for Pneumology and Critical Care Medicine, Thoraxklinik Heidelberg, Heidelberg, Germany.
- Department 2 of Internal Medicine, Infectious Diseases, University Hospital Frankfurt, Goethe University Frankfurt, Frankfurt am Main, Germany.
- Department I of Internal Medicine, Division of Infectious Diseases, Medical Faculty and University Hospital of Cologne, University of Cologne, Cologne Germany.
ORCID-Profile: Stefan Fabian Weber, Nils Wetzstein, Claus Küpper-Tetzel, Lisa Koeppel, Julia Selena Beck, Rebecca Wolf, Devasahayam Jesudas Christopher, Claudia M Denkinger
Förderung
- DZIF
- Center for Infectious Disease Research
Zitieren
APA
Weber, S. F., Wolf, P., Wetzstein, N., Küpper-Tetzel, C., Vehreschild, M., Suárez, I., Rybniker, J., Klingmüller, A., Weber, T., Güttlein, M., Tobian, F., Koeppel, L., Beck, J. S., Wolf, R., Manten, K., Zimmermann, S., Christopher, D. J., Herth, F., Bélard, S., …, & ALL POCUS TB Germany Study group (2024). Diagnostic Accuracy of Lung and Abdominal Ultrasound for Tuberculosis in a German Multicenter Cohort of Patients With Presumed Tuberculosis Disease. Open Forum Infectious Diseases, 11(12). https://doi.org/10.1093/ofid/ofae651
Vancouver
Weber SF, Wolf P, Wetzstein N, Küpper-Tetzel C, Vehreschild M, Suárez I, et al. Diagnostic Accuracy of Lung and Abdominal Ultrasound for Tuberculosis in a German Multicenter Cohort of Patients With Presumed Tuberculosis Disease. Open Forum Infectious Diseases. 2024;11(12). doi:10.1093/ofid/ofae651
BibTeX
@article{Weber2024,
author = {Weber, Stefan Fabian and Wolf, Peter and Wetzstein, Nils and Küpper-Tetzel, Claus and Vehreschild, Maria and Suárez, Isabelle and Rybniker, Jan and Klingmüller, Angela and Weber, Tim and Güttlein, Maximilian and Tobian, Frank and Koeppel, Lisa and Beck, Julia Selena and Wolf, Rebecca and Manten, Katharina and Zimmermann, Stefan and Christopher, Devasahayam Jesudas and Herth, Felix and Bélard, Sabine and Denkinger, Claudia M and ALL POCUS TB Germany Study group, ALL POCUS TB Germany Study group},
title = {Diagnostic Accuracy of Lung and Abdominal Ultrasound for Tuberculosis in a German Multicenter Cohort of Patients With Presumed Tuberculosis Disease},
journal = {Open Forum Infectious Diseases},
year = {2024},
volume = {11},
number = {12},
doi = {10.1093/ofid/ofae651}
}
EUVIMED