Evaluation of Sonicate Fluid Culture Cutoff Points for Periprosthetic Joint Infection Diagnosis
Open Forum Infectious Diseases · 26.04.2024 · 11 (5)
DOI: 10.1093/ofid/ofae159 ↗Kurz gefasst
Fachartikel in der Zeitschrift Open Forum Infectious Diseases, online erschienen am 20.03.2024. Verfasst von Judith Alvarez Otero und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, USA. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIAMS NIH HHS, National Institute of Arthritis and Musculoskeletal and Skin Diseases, National Institutes of Health.
Abstract (Originalsprache)
Introduction
Implant sonication is useful for recovery of periprosthetic joint infection (PJI) pathogens in culture, but exact cutoff points for definition of clinically significant sonicate fluid culture results vary from study to study. The aim of this study was to define ideal sonicate fluid culture cutoff points for PJI diagnosis.
Methods
Sonicate fluid cultures from hip and knee prosthesis components removed between February 2007 and December 2020 were studied. Prosthesis components were placed in solid containers in the operating room; in the clinical microbiology laboratory, 400 mL Ringer's solution was added, and containers subjected to vortexing, sonication and then vortexing, followed by centrifugation. Concentrated sonicate fluid was plated on aerobic and anaerobic solid media, and culture results reported semiquantitatively, as no growth, <20, 20–50, 51–100, or >100 CFU/10 mL sonicate fluid. Sonicate cultures from cement spacers and cultures yielding more than 1 microorganism were excluded. Sensitivity and specificity of each cutoff point was evaluated.
Results
A total of 1448 sonicate fluid cultures were evaluated, 68% from knees and 32% from hips. PJI was present in 644 (44%) cases. Sensitivity of sonicate culture was 75.0% at <20 CFU/10 mL, 55.3% at ≥20 CFU/10 mL, 46.9% at >51 CFU/10 mL, and 39.8% at >100 CFU/10 mL. Specificity was 78.2%, 99.8%, 100%, and 100%, at the 4 cutoff points, respectively.
Conclusions
A cutoff point for sonicate fluid culture positivity of ≥20 CFU/10 mL is suitable for PJI diagnosis.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Clinical Microbiology, Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, USA.
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA.
- Department of Quantitative Health Sciences, Mayo Clinic, Rochester, Minnesota, USA.
- Division of Public Health, Infectious Diseases, and Occupational Medicine, Department of Medicine, Mayo Clinic, Rochester, Minnesota, USA.
ORCID-Profile: Robin Patel
Förderung
- NIAMS NIH HHS
- National Institute of Arthritis and Musculoskeletal and Skin Diseases
- National Institutes of Health
Zitieren
APA
Alvarez Otero, J., Karau, M. J., Greenwood-Quaintance, K. E., Abdel, M. P., Mandrekar, J., & Patel, R. (2024). Evaluation of Sonicate Fluid Culture Cutoff Points for Periprosthetic Joint Infection Diagnosis. Open Forum Infectious Diseases, 11(5). https://doi.org/10.1093/ofid/ofae159
Vancouver
Alvarez Otero J, Karau MJ, Greenwood-Quaintance KE, Abdel MP, Mandrekar J, Patel R. Evaluation of Sonicate Fluid Culture Cutoff Points for Periprosthetic Joint Infection Diagnosis. Open Forum Infectious Diseases. 2024;11(5). doi:10.1093/ofid/ofae159
BibTeX
@article{AlvarezOtero2024,
author = {Alvarez Otero, Judith and Karau, Melissa J and Greenwood-Quaintance, Kerryl E and Abdel, Matthew P and Mandrekar, Jay and Patel, Robin},
title = {Evaluation of Sonicate Fluid Culture Cutoff Points for Periprosthetic Joint Infection Diagnosis},
journal = {Open Forum Infectious Diseases},
year = {2024},
volume = {11},
number = {5},
doi = {10.1093/ofid/ofae159}
}
EUVIMED