EUVIMEDEUVIMED entdecken
Vergleichsstudie

Office or home versus 24-h blood pressure measurement in stable kidney transplant recipients

Georgios Eleftheriadis, Marcel G Naik, Bilgin Osmanodja, Fabian Halleck, Eva Schrezenmeier, Lutz Liefeldt, Mira Choi, Friederike Bachmann, Despina Parthenopi Avaniadi, Ellen von Hoerschelmann, Christian Lücht, Marina Zaks und 2 weitere

Nephrology Dialysis Transplantation · 2024

DOI: 10.1093/ndt/gfae076 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Nephrology Dialysis Transplantation, 2024. Verfasst von Georgios Eleftheriadis und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nephrology and Medical Intensive Care, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-…. Hauptthemen laut MEDLINE: Kidney Transplantation, Blood Pressure Monitoring, Ambulatory, Hypertension. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Berlin Institute of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The aim of this study was to quantify hypertension control and evaluate concordance between all commonly available blood pressure (BP) modalities in kidney transplant recipients (KTRs).

Methods

For this prospective cross-sectional study, 89 stable KTRs were recruited at the Charité Transplant Outpatient Clinic. For each study participant office [manual office BP (MOBP) and automated office BP (AOBP)], 7-day home (HBPM) and 24-hour ambulatory BP (24h-ABPM) measurements were performed.

Results

80 of the 89 patients recruited had sufficient BP recordings. The mean BP for MOBP, AOBP, HBPM and 24h-ABPM was 129/73, 126/71, 131/85 and 130/81 mmHg, respectively. Uncontrolled hypertension, as defined by 24h-ABPM (mean ≥130/80 mmHg), was present in 53 (66%) patients. MOBP, AOBP and HBPM classified 19 (24%), 22 (28%) and 41 (51%) patients, respectively, as ‘uncontrolled hypertensive’. The Bland–Altman plot showed good agreement between systolic MOBP, AOBP, HBPM and daytime-ABPM (mean bias: −1 ± 13 mmHg, −4 ± 13 mmHg, 1 ± 10 mmHg, respectively). Uncontrolled night-time hypertension was present in 74 (93%) KTRs, with 71 (89%) patients showing a non-physiological dipping pattern. Moderate positive correlation between daytime-ABPM/HBPM and night-time-ABPM (Pearson correlation coefficients: 0.62–0.73), followed by MOBP/AOBP (Pearson correlation coefficients: 0.49–0.59) was noted. Estimated eGFR and proteinuria displayed weak correlation with 24h-, daytime- and night-time-ABPM (absolute values of Pearson correlation coefficients: 0.04–0.41). No robust association with either 24h-, daytime- or night-time-ABPM was observed for volume status exams.

Conclusions

Masked hypertension is highly prevalent in KTRs, especially due to high rates of uncontrolled night-time hypertension. HBPM shows the narrowest limits of agreement with daytime-ABPM. Daytime-ABPM and HBPM show the highest, albeit clinically insufficient, correlation with night-time-ABPM. Systematic integration of 24h-ABPM into clinical practice, as proposed by the 2023 ESH guidelines for the management of arterial hypertension, should not be withheld for the KTR population. Clinical trials evaluating the treatment of hypertension in KTRs are urgently needed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Kidney TransplantationBlood Pressure Monitoring, AmbulatoryHypertensionHumansFemaleMaleMiddle AgedProspective StudiesCross-Sectional StudiesBlood PressureTransplant RecipientsFollow-Up StudiesPrognosisBlood Pressure DeterminationAdultAgedKidney Failure, Chronic

Stichwörter der Autor:innen

ambulatory blood pressure measurement (ABPM)automated office blood pressure (AOBP)home blood pressure measurement (HBPM)kidney transplantationmanual office blood pressure (MOBP)

Autor:innen und Institutionen

  • Department of Nephrology and Medical Intensive Care, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
  • Berlin Institute of Health, Berlin, Germany.

Förderung

  • Berlin Institute of Health

Zitieren

APA

Eleftheriadis, G., Naik, M. G., Osmanodja, B., Halleck, F., Schrezenmeier, E., Liefeldt, L., Choi, M., Bachmann, F., Avaniadi, D. P., von Hoerschelmann, E., Lücht, C., Zaks, M., Duettmann, W., & Budde, K. (2024). Office or home versus 24-h blood pressure measurement in stable kidney transplant recipients. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfae076

Vancouver

Eleftheriadis G, Naik MG, Osmanodja B, Halleck F, Schrezenmeier E, Liefeldt L, et al. Office or home versus 24-h blood pressure measurement in stable kidney transplant recipients. Nephrology Dialysis Transplantation. 2024. doi:10.1093/ndt/gfae076

BibTeX
@article{Eleftheriadis2024,
  author = {Eleftheriadis, Georgios and Naik, Marcel G and Osmanodja, Bilgin and Halleck, Fabian and Schrezenmeier, Eva and Liefeldt, Lutz and Choi, Mira and Bachmann, Friederike and Avaniadi, Despina Parthenopi and von Hoerschelmann, Ellen and Lücht, Christian and Zaks, Marina and Duettmann, Wiebke and Budde, Klemens},
  title = {Office or home versus 24-h blood pressure measurement in stable kidney transplant recipients},
  journal = {Nephrology Dialysis Transplantation},
  year = {2024},
  doi = {10.1093/ndt/gfae076}
}
Kostenlos starten →