Randomized trial comparing standard versus thermocontrolled haemodialysis using intradialytic cardiac, brain and renal magnetic resonance imaging
Nephrology Dialysis Transplantation · 2024
DOI: 10.1093/ndt/gfad150 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Nephrology Dialysis Transplantation, 2024. Verfasst von Venkata R Latha Gullapudi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Kidney Research and Innovation, University of Nottingham, Derby, UK. Hauptthemen laut MEDLINE: Renal Dialysis, Kidney Failure, Chronic. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Fresenius Medical Care.
Abstract (Originalsprache)
Background
Ischaemic end-organ damage during haemodialysis (HD) is a significant problem that may be ameliorated by intradialytic cooling. A randomised trial was performed to compare standard HD (SHD; dialysate temperature 37°C) and programmed cooling of the dialysate [thermocontrolled HD (TCHD)] using multiparametric magnetic resonance imaging (MRI) to assess structural, functional and blood flow changes in the heart, brain and kidneys.
Methods
Prevalent HD patients were randomly allocated to receive either SHD or TCHD for 2 weeks before undergoing serial MRI at four time points: pre-, during (30 min and 180 min) and post-dialysis. MRI measures include cardiac index, myocardial strain, longitudinal relaxation time (T1), myocardial perfusion, internal carotid and basilar artery flow, grey matter perfusion and total kidney volume. Participants then crossed to the other modality to repeat the study protocol.
Results
Eleven participants completed the study. Separation in blood temperature between TCHD (−0.1 ± 0.3°C) and SHD (+0.3 ± 0.2°C; P = .022) was observed, although there was no difference in tympanic temperature changes between arms. There were significant intradialytic reductions in cardiac index, cardiac contractility (left ventricular strain), left carotid and basilar artery blood flow velocities, total kidney volume, longitudinal relaxation time (T1) of the renal cortex and transverse relaxation rate (T2*) of the renal cortex and medulla, but no differences between arms. Pre-dialysis T1 of the myocardium and left ventricular wall mass index were lower after 2 weeks of TCHD compared with SHD [1266 ms (interquartile range 1250–1291) versus 1311 ± 58 ms, P = .02; 66 ± 22 g/m2 versus 72 ± 23 g/m2, P = .004].
Conclusions
HD adversely affects cardiac function, reduces carotid and basilar artery blood flow and total kidney volume, but mild dialysate cooling using a biofeedback module did not result in differences in intradialytic MRI measures compared with SHD.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Centre for Kidney Research and Innovation, University of Nottingham, Derby, UK.
- Department of Renal Medicine, University Hospitals of Derby and Burton NHS Foundation Trust, Derby, UK.
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK.
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK.
- Global Medical Office, Fresenius Medical Care, Bad Homburg, Germany.
ORCID-Profile: Venkata R Latha Gullapudi, Eleanor F Cox, Charlotte E Buchanan, Maarten W Taal, Nicholas M Selby
Förderung
- Fresenius Medical Care
Zitieren
APA
Gullapudi, V. R. L., Cox, E. F., Buchanan, C. E., Canaud, B., White, K., Taal, M. W., Selby, N. M., & Francis, S. T. (2024). Randomized trial comparing standard versus thermocontrolled haemodialysis using intradialytic cardiac, brain and renal magnetic resonance imaging. Nephrology Dialysis Transplantation. https://doi.org/10.1093/ndt/gfad150
Vancouver
Gullapudi VRL, Cox EF, Buchanan CE, Canaud B, White K, Taal MW, et al. Randomized trial comparing standard versus thermocontrolled haemodialysis using intradialytic cardiac, brain and renal magnetic resonance imaging. Nephrology Dialysis Transplantation. 2024. doi:10.1093/ndt/gfad150
BibTeX
@article{Gullapudi2024,
author = {Gullapudi, Venkata R Latha and Cox, Eleanor F and Buchanan, Charlotte E and Canaud, Bernard and White, Kelly and Taal, Maarten W and Selby, Nicholas M and Francis, Susan T},
title = {Randomized trial comparing standard versus thermocontrolled haemodialysis using intradialytic cardiac, brain and renal magnetic resonance imaging},
journal = {Nephrology Dialysis Transplantation},
year = {2024},
doi = {10.1093/ndt/gfad150}
}
EUVIMED