Fluorescent modifications in aptamer switches—positional, structural, and neighboring pair effects on sensor performance
Nucleic Acids Research · 2025
DOI: 10.1093/nar/gkaf1346 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nucleic Acids Research, 2025. Verfasst von Albert Zehan Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Biosensing Techniques, Fluorescent Dyes. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Canada Foundation for Innovation.
Abstract (Originalsprache)
Aptamers are modular nucleic acid ligands increasingly used as recognition elements in biosensors for precision medicine. Their structure facilitates their adaptation into fluorescent switches through molecular design and conjugation with reporter molecules, which are typically selected based on optimal photophysical compatibility. However, a critical challenge persists: reporter molecules are not inert; their structure and underlying conjugation chemistry can introduce structural perturbations that adversely affect aptamer functional properties and DNA-duplex stability, subsequently impacting biosensing performance. Here, we evaluate the effect of fluorophore–quencher modifications by probing the interplay between reporter identity, local environment, and labeling positions within different switch architectures. We demonstrate that applying a combinatorial array of modifications to an aptamer switch sequence can tune its binding properties over a 2-order-of-magnitude range, with apparent binding affinities from ~230 to 2.3 μM and apparent kinetic response rates from ~1000 s to sub-second resolution, while also influencing the switch’s specificity and signal resolution. We also establish that the environment and spatial positioning of a reporter pair are critical design parameters, enabling order-of-magnitude performance differences even at theoretically suboptimal sites. This work provides a comprehensive study to help design optimal switches when using fluorescent modifications, enabling the development of next-generation biosensors with tailored performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, University of British Columbia, Vancouver, British Columbia V6T 1Z1, Canada.
- Djavad Mowafaghian Centre for Brain Health, University of British Columbia, Vancouver, British Columbia V6T 1Z3, Canada.
ORCID-Profile: Amani A Hariri
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Canada Foundation for Innovation
Zitieren
APA
Li, A. Z., Belzberg, C. H. T., Sidhu, M., & Hariri, A. A. (2025). Fluorescent modifications in aptamer switches—positional, structural, and neighboring pair effects on sensor performance. Nucleic Acids Research. https://doi.org/10.1093/nar/gkaf1346
Vancouver
Li AZ, Belzberg CHT, Sidhu M, Hariri AA. Fluorescent modifications in aptamer switches—positional, structural, and neighboring pair effects on sensor performance. Nucleic Acids Research. 2025. doi:10.1093/nar/gkaf1346
BibTeX
@article{Li2025,
author = {Li, Albert Zehan and Belzberg, Conrad H T and Sidhu, Mimansa and Hariri, Amani A},
title = {Fluorescent modifications in aptamer switches—positional, structural, and neighboring pair effects on sensor performance},
journal = {Nucleic Acids Research},
year = {2025},
doi = {10.1093/nar/gkaf1346}
}
EUVIMED