MMCT-Loop: a mix model-based pipeline for calling targeted 3D chromatin loops
Nucleic Acids Research · 2024
DOI: 10.1093/nar/gkae029 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nucleic Acids Research, 2024. Verfasst von Li Tang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Hunan Provincial Key Lab on Bioinformatics, School of Computer Science and Engineering, Central South University, Changsha 410083, China. Hauptthemen laut MEDLINE: Chromatin, Genomics, Genetic Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Natural Science Foundation of China, Hunan Provincial Science and Technology Program, Postdoctoral Fellowship Program of CPSF.
Abstract (Originalsprache)
Protein-specific Chromatin Conformation Capture (3C)-based technologies have become essential for identifying distal genomic interactions with critical roles in gene regulation. The standard techniques include Chromatin Interaction Analysis by Paired-End Tag (ChIA-PET), in situ Hi-C followed by chromatin immunoprecipitation (HiChIP) also known as PLAC-seq. To identify chromatin interactions from these data, a variety of computational methods have emerged. Although these state-of-art methods address many issues with loop calling, only few methods can fit different data types simultaneously, and the accuracy as well as the efficiency these approaches remains limited. Here we have generated a pipeline, MMCT-Loop, which ensures the accurate identification of strong loops as well as dynamic or weak loops through a mixed model. MMCT-Loop outperforms existing methods in accuracy, and the detected loops show higher activation functionality. To highlight the utility of MMCT-Loop, we applied it to conformational data derived from neural stem cell (NSCs) and uncovered several previously unidentified regulatory regions for key master regulators of stem cell identity. MMCT-Loop is an accurate and efficient loop caller for targeted conformation capture data, which supports raw data or pre-processed valid pairs as input, the output interactions are formatted and easily uploaded to a genome browser for visualization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Hunan Provincial Key Lab on Bioinformatics, School of Computer Science and Engineering, Central South University, Changsha 410083, China.
- Cardiovascular Research Center, Massachusetts General Hospital, Boston, MA 02129, USA.
- Cardiovascular Disease Initiative, The Broad Institute of Harvard and MIT, Cambridge, MA 02142, USA.
ORCID-Profile: Min Li
Förderung
- National Natural Science Foundation of China
- Hunan Provincial Science and Technology Program
- Postdoctoral Fellowship Program of CPSF
Zitieren
APA
Tang, L., Liao, J., Hill, M. C., Hu, J., Zhao, Y., Ellinor, P. T., & Li, M. (2024). MMCT-Loop: a mix model-based pipeline for calling targeted 3D chromatin loops. Nucleic Acids Research. https://doi.org/10.1093/nar/gkae029
Vancouver
Tang L, Liao J, Hill MC, Hu J, Zhao Y, Ellinor PT, et al. MMCT-Loop: a mix model-based pipeline for calling targeted 3D chromatin loops. Nucleic Acids Research. 2024. doi:10.1093/nar/gkae029
BibTeX
@article{Tang2024,
author = {Tang, Li and Liao, Jiaqi and Hill, Matthew C and Hu, Jiaxin and Zhao, Yichao and Ellinor, Patrick T and Li, Min},
title = {MMCT-Loop: a mix model-based pipeline for calling targeted 3D chromatin loops},
journal = {Nucleic Acids Research},
year = {2024},
doi = {10.1093/nar/gkae029}
}
EUVIMED