EUVIMEDEUVIMED entdecken
Crossref

Visual comet scoring revisited: a guide to scoring comet assay slides and obtaining reliable results

Peter Møller iD, Amaya Azqueta, Julen Sanz-Serrano iD, Tamara Bakuradze, Elke Richling, Ezgi Eyluel Bankoglu, Helga Stopper, Victoria Claudino Bastos, Sabine A S Langie, Annie Jensen, Francesca Scavone, Lisa Giovannelli und 13 weitere

Mutagenesis · 14.10.2023 · 38 (5) · 253-263

DOI: 10.1093/mutage/gead015 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Mutagenesis, online erschienen am 26.05.2023. Verfasst von Peter Møller und 24 weiteren Autor:innen. Beteiligte Einrichtung: Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade 5A, DK-1014 Copenhagen K, Denmark. Hauptthemen laut MEDLINE: Comet Assay. Die Arbeit wurde bisher 37-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Spanish Ministry of Science and Innovation, Xunta de Galicia, Università degli Studi di Firenze.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Measurement of DNA migration in the comet assay can be done by image analysis or visual scoring. The latter accounts for 20%–25% of the published comet assay results. Here we assess the intra- and inter-investigator variability in visual scoring of comets. We include three training sets of comet images, which can be used as reference for researchers who wish to use visual scoring of comets. Investigators in 11 different laboratories scored the comet images using a five-class scoring system. There is inter-investigator variation in the three training sets of comets (i.e. coefficient of variation (CV) = 9.7%, 19.8%, and 15.2% in training sets I–III, respectively). However, there is also a positive correlation of inter-investigator scoring in the three training sets (r = 0.60). Overall, 36% of the variation is attributed to inter-investigator variation and 64% stems from intra-investigator variation in scoring between comets (i.e. the comets in training sets I–III look slightly different and this gives rise to heterogeneity in scoring). Intra-investigator variation in scoring was also assessed by repeated analysis of the training sets by the same investigator. There was larger variation when the training sets were scored over a period of six months (CV = 5.9%–9.6%) as compared to 1 week (CV = 1.3%–6.1%). A subsequent study revealed a high inter-investigator variation when premade slides, prepared in a central laboratory, were stained and scored by investigators in different laboratories (CV = 105% and 18%–20% in premade slides with comets from unexposed and hydrogen peroxide-exposed cells, respectively). The results indicate that further standardization of visual scoring is desirable. Nevertheless, the analysis demonstrates that visual scoring is a reliable way of analysing DNA migration in comets.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Comet AssayHumansObserver VariationReproducibility of ResultsDNA DamageImage Processing, Computer-Assisted

Stichwörter der Autor:innen

Comet AssayDNA damageRing trialValidationVisual scoring

Autor:innen und Institutionen

  • Department of Public Health, Section of Environmental Health, University of Copenhagen, Øster Farimagsgade 5A, DK-1014 Copenhagen K, Denmark.
  • Department of Pharmacology and Toxicology, School of Pharmacy and Nutrition. University of Navarra, C/Irunlarrea 1, 31009 Pamplona, Spain.
  • Food Chemistry and Toxicology, Department of Chemistry, RPTU Kaiserslautern-Landau, Erwin-Schroedinger-Str. 52, D-67663 Kaiserslautern, Germany.
  • Institute of Pharmacology and Toxicology, University of Würzburg, Versbacher Str. 9, 97078 Wuerzburg, Germany.
  • Department of Pharmacology & Toxicology, School for Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, The Netherlands.
  • Department of Neuroscience, Psychology, Pharmacology and Child Health (NEUROFARBA), Section Pharmacology and Toxicology, University of Florence, Florence, Italy.

ORCID-Profile: Peter Møller, Julen Sanz-Serrano, Vanessa Valdiglesias, João Paulo Teixeira, Mirko Marino

Förderung

  • Spanish Ministry of Science and Innovation
  • Xunta de Galicia
  • Università degli Studi di Firenze

Zitieren

APA

Møller, P., Azqueta, A., Sanz-Serrano, J., Bakuradze, T., Richling, E., Eyluel Bankoglu, E., Stopper, H., Claudino Bastos, V., Langie, S. A. S., Jensen, A., Scavone, F., Giovannelli, L., Wojewódzka, M., Kruszewski, M., Valdiglesias, V., Laffon, B., Costa, C., Costa, S., Teixeira, J. P., …, & Collins, A. (2023). Visual comet scoring revisited: a guide to scoring comet assay slides and obtaining reliable results. Mutagenesis, 38(5), 253-263. https://doi.org/10.1093/mutage/gead015

Vancouver

Møller P, Azqueta A, Sanz-Serrano J, Bakuradze T, Richling E, Eyluel Bankoglu E, et al. Visual comet scoring revisited: a guide to scoring comet assay slides and obtaining reliable results. Mutagenesis. 2023;38(5):253-263. doi:10.1093/mutage/gead015

BibTeX
@article{Mller2023,
  author = {Møller, Peter and Azqueta, Amaya and Sanz-Serrano, Julen and Bakuradze, Tamara and Richling, Elke and Eyluel Bankoglu, Ezgi and Stopper, Helga and Claudino Bastos, Victoria and Langie, Sabine A S and Jensen, Annie and Scavone, Francesca and Giovannelli, Lisa and Wojewódzka, Maria and Kruszewski, Marcin and Valdiglesias, Vanessa and Laffon, Blanca and Costa, Carla and Costa, Solange and Teixeira, João Paulo and Marino, Mirko and Del Bo, Cristian and Riso, Patrizia and Zheng, Congying and Shaposhnikov, Sergey and Collins, Andrew},
  title = {Visual comet scoring revisited: a guide to scoring comet assay slides and obtaining reliable results},
  journal = {Mutagenesis},
  year = {2023},
  volume = {38},
  number = {5},
  pages = {253--263},
  doi = {10.1093/mutage/gead015}
}
Kostenlos starten →