EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Test of a 34 GHz EOM laser frequency comb at ESPRESSO

Tobias M Schmidt, Ewelina Obrzud, François Bouchy, Gaspare Lo Curto, Victor Brasch, Tobias Herr, Furkan Ayhan, Severine Denis, Davide Grassani, Jean Berney, Bruno Chazelas, Weichen Fan und 9 weitere

Monthly Notices of the Royal Astronomical Society · 06.04.2026 · 548 (1)

DOI: 10.1093/mnras/stag426 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Monthly Notices of the Royal Astronomical Society, online erschienen am 19.03.2026. Verfasst von Tobias M Schmidt und 20 weiteren Autor:innen. Die Arbeit nennt 84 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: SNF, Swiss National Science Foundation, European Research Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Laser frequency combs (LFCs) are a promising technology for wavelength calibration of astronomical high-resolution spectrographs requiring utmost accuracy and stability, since they directly translate the fundamental SI time standard from the radio frequency regime to optical frequencies. However, they have so far seen limited use in practice, due to their complexity, incomplete wavelength coverage, but also the challenges in the data analysis they imply. Here, we present a detailed test of a $34\, \mathrm{GHz}$ electro-optic modulation comb with the Echelle SPectrograph for Rocky Exoplanets and Stable Spectroscopic Observations (ESPRESSO) spectrograph. Using thin-film lithum-niobate waveguides for broadening and harmonic generation, the setup provides partial coverage of the infrared, visible, and near-ultraviolet spectral ranges. We focus on assessing the quality of the delivered spectra and their capability to facilitate accurate and stable wavelength calibration. We present a detailed analysis of the spectrally diffuse background, the line width, and characterize the line-spread function over a broader width than possible with the ESPRESSO facility LFC. Comparing both combs, we find strong local discrepancies in the wavelength calibration accuracy up to $15\, \mbox{m}\, \mbox{s}^{-1}$, which correlate with the echellogram structure. These do not originate from the lasers, but from misalignments in the ESPRESSO calibration unit, highlighting the strong need to make instrument fibre feeds more robust to light-injection effects. Nevertheless, we demonstrate excellent stability of the wavelength calibration, with a scatter of only $17\, \mbox{cm}\, \mbox{s}^{-1}$. This, however, can only be achieved when accurately modelling the non-Gaussian line-spread function, showcasing the need for advanced data analysis techniques when dealing with LFC spectra.

Förderung

  • SNF
  • Swiss National Science Foundation
  • European Research Council
  • ESO

Zitieren

APA

Schmidt, T. M., Obrzud, E., Bouchy, F., Curto, G. L., Brasch, V., Herr, T., Ayhan, F., Denis, S., Grassani, D., Berney, J., Chazelas, B., Fan, W., Holzer, J., Hughes, I., Ludwig, M., Manescau, A., Pasquini, L., Pepe, F., Villanueva, L. G., …, & Wildi, T. (2026). Test of a 34 GHz EOM laser frequency comb at ESPRESSO. Monthly Notices of the Royal Astronomical Society, 548(1). https://doi.org/10.1093/mnras/stag426

Vancouver

Schmidt TM, Obrzud E, Bouchy F, Curto GL, Brasch V, Herr T, et al. Test of a 34 GHz EOM laser frequency comb at ESPRESSO. Monthly Notices of the Royal Astronomical Society. 2026;548(1). doi:10.1093/mnras/stag426

BibTeX
@article{Schmidt2026,
  author = {Schmidt, Tobias M and Obrzud, Ewelina and Bouchy, François and Curto, Gaspare Lo and Brasch, Victor and Herr, Tobias and Ayhan, Furkan and Denis, Severine and Grassani, Davide and Berney, Jean and Chazelas, Bruno and Fan, Weichen and Holzer, Jannis and Hughes, Ian and Ludwig, Markus and Manescau, Antonio and Pasquini, Luca and Pepe, Francesco and Villanueva, Luis Guillermo and Wildi, François and Wildi, Thibault},
  title = {Test of a 34 GHz EOM laser frequency comb at ESPRESSO},
  journal = {Monthly Notices of the Royal Astronomical Society},
  year = {2026},
  volume = {548},
  number = {1},
  doi = {10.1093/mnras/stag426}
}
Kostenlos starten →