EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Impact of numerical stability in Bayesian noise wave calibration on global 21-cm experiments

Saswata Dasgupta, Adarsh Kumar Dash, Dominic Anstey, Harry T J Bevins, Christian Kirkham, Eloy de Lera Acedo

Monthly Notices of the Royal Astronomical Society · 11.11.2026

DOI: 10.1093/mnras/stag2108 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Monthly Notices of the Royal Astronomical Society, online erschienen am 11.11.2026. Verfasst von Saswata Dasgupta und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Detecting the global 21-cm signal from the Cosmic Dawn and Epoch of Reionization requires calibration accuracy far below the level of astrophysical foregrounds. REACH models its receiver using the noise wave formalism, with five frequency-dependent low-noise amplifier parameters fitted jointly to multiple calibration sources. We identify a numerical instability in this Bayesian calibration pipeline: the condition number of the posterior covariance matrix reaches κ(V*) ~ 109–1011, making solutions non-reproducible across computing environments. Singular value decomposition shows that the instability is driven by near-collinearity between the design-matrix columns associated with the excess noise source temperature, XNS, and the load temperature, XL. Using a Chebyshev basis, we develop a two-step mitigation. First, fixing TNS to a scalar removes the degeneracy and reduces κ(V*) to ~60. Second, to retain frequency dependence, we recover TNS(ν) directly from the hot-load calibration measurement. On mock data, this method preserves the stability of the reduced model while achieving comparable calibration accuracy. Masking narrow channels around cable standing-wave degeneracies further removes local artefacts in the design matrix. These steps provide a stable, reproducible, and data-driven calibration procedure. Because the XNS–XL degeneracy is inherent to the noise wave formalism, the method is relevant to other global 21-cm experiments.

Zitieren

APA

Dasgupta, S., Dash, A. K., Anstey, D., Bevins, H. T. J., Kirkham, C., & Acedo, E. D. L. (2026). Impact of numerical stability in Bayesian noise wave calibration on global 21-cm experiments. Monthly Notices of the Royal Astronomical Society. https://doi.org/10.1093/mnras/stag2108

Vancouver

Dasgupta S, Dash AK, Anstey D, Bevins HTJ, Kirkham C, Acedo EDL. Impact of numerical stability in Bayesian noise wave calibration on global 21-cm experiments. Monthly Notices of the Royal Astronomical Society. 2026. doi:10.1093/mnras/stag2108

BibTeX
@article{Dasgupta2026,
  author = {Dasgupta, Saswata and Dash, Adarsh Kumar and Anstey, Dominic and Bevins, Harry T J and Kirkham, Christian and Acedo, Eloy de Lera},
  title = {Impact of numerical stability in Bayesian noise wave calibration on global 21-cm experiments},
  journal = {Monthly Notices of the Royal Astronomical Society},
  year = {2026},
  doi = {10.1093/mnras/stag2108}
}
Kostenlos starten →