Sensor Design for Ankle Resiliency Training
Military Medicine · 01.08.2026 · 191 (Supplement_1) · 621-630
DOI: 10.1093/milmed/usag198 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Military Medicine, online erschienen am 06.08.2026. Verfasst von Ashwin Iyer und 6 weiteren Autor:innen. Beteiligte Einrichtung: Altec Inc, Natick, MA 01760, United States. Hauptthemen laut MEDLINE: Ankle Injuries, Equipment Design, Muscle, Skeletal, Electromyography. Die Arbeit nennt 35 Literaturangaben. Gefördert von: Medical Technology Research Consortium.
Abstract (Originalsprache)
Introduction
Lateral ankle sprains (LASs) are among the most common musculoskeletal injuries and are a leading cause of limited duty days among service members. Rehabilitation and prevention strategies focus on strengthening the peroneus longus (PL) muscle as a protection mechanism, however clinical assessments of PL engagement during training are qualitative and require expert evaluation. Existing surface electromyography (sEMG) technologies allow noninvasive estimations of muscle activation, but are limited when energy from neighboring muscles (crosstalk) reaches detection sites at anatomically constrained muscles like the PL. To address this gap, we introduce the Ankle REsiliency System (ARES), a hardware-software platform that integrates high-density sEMG with custom signal processing algorithms to isolate and quantify PL workload during functional exercises. Materials and Methods ARES consists of a high density sEMG electrode array equipped with custom signal processing firmware and software which streams high fidelity sEMG data and quantifies PL workload during functional exercises. System validation was conducted with 5 healthy male participants (21-35 years). Algorithm validation was performed on isolated tasks of eversion and dorsiflexion, where PL workload estimates were compared against true labels provided by bipolar sEMG recordings. Full system validation was then performed during 5 biomechanically relevant exercises designed to challenge the PL across varying intensity levels.
Results
For isolated tasks, ARES achieved 93.3% ± 1.1% accuracy in distinguishing PL activity from crosstalk. During dynamic exercises, ARES detected workload increases between low and high force exercises (P < .05).
Conclusions
Our work describes the design of ARES by integrating sEMG hardware and signal processing algorithms into a tool to assess PL workload during functional exercises. Results show an ability to robustly differentiate between crosstalk and PL activity highlighting potential utility to assist in injury-prevention or rehabilitation outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Altec Inc, Natick, MA 01760, United States.
- Delsys Inc, Natick, MA 01760, United States.
- Warfighter Performance Department, Naval Health Research Center, San Diego, CA 92152, United States.
ORCID-Profile: Ashwin Iyer, John P Chiodini
Förderung
- Medical Technology Research Consortium
Zitieren
APA
Iyer, A., Silder, A., Lassard, H., Roy, S. H., De Luca, G., Kline, J., & Chiodini, J. P. (2026). Sensor Design for Ankle Resiliency Training. Military Medicine, 191(Supplement_1), 621-630. https://doi.org/10.1093/milmed/usag198
Vancouver
Iyer A, Silder A, Lassard H, Roy SH, De Luca G, Kline J, et al. Sensor Design for Ankle Resiliency Training. Military Medicine. 2026;191(Supplement_1):621-630. doi:10.1093/milmed/usag198
BibTeX
@article{Iyer2026,
author = {Iyer, Ashwin and Silder, Amy and Lassard, Hunter and Roy, Serge H and De Luca, Gianluca and Kline, Joshua and Chiodini, John P},
title = {Sensor Design for Ankle Resiliency Training},
journal = {Military Medicine},
year = {2026},
volume = {191},
number = {Supplement_1},
pages = {621--630},
doi = {10.1093/milmed/usag198}
}
EUVIMED