Comparison of Axial Force Attenuation Characteristics in Two Different Lower Extremity Anthropomorphic Test Devices

Sajal Chirvi, Frank A Pintar iD, Narayan Yoganandan iD, B Joseph McEntire

Military Medicine · 2023

DOI: 10.1093/milmed/usad310 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Military Medicine, 2023. Verfasst von Sajal Chirvi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering and Neurosurgery, Medical College of Wisconsin and VA Medical Center, 5000, W. National Avenue, Milwaukee, WI 53295, USA. Hauptthemen laut MEDLINE: Lower Extremity, Leg. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Medical Research and Materiel Command.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Any type of boot or footwear is designed to attenuate and distribute loading to the bottom of the foot. Anthropomorphic test device (ATDs) are used to assess potential countermeasures against these loads. The specific aims of this study were to compare and quantify force attenuation characteristics as a function of input energy for Hybrid-III and Mil-Lx ATD human surrogates. Materials and methods Two lower leg ATD surrogates (Mil-Lx and Hybrid-III) were tested to investigate the influence of a commercially available military boot on lower extremity force response and assess such differences against previously published postmortem human surrogate studies. The testing apparatus impacted the bottom of the foot using a rigid plate at velocities from 2 to 10 m/s. Tests were conducted on each ATD to obtain axial force response with and without boots as a function of input energy.

Results

Peak forces ranged from 1 to 16.4 kN for the Hybrid-III, and 1 to 8.4 kN for the Mil-Lx for similar input conditions. The average force attenuation for the Hybrid-III at upper and lower load cells was 71% (59%–80%) and 70% (58%–78%). The average attenuation for the Mil-Lx at upper and lower load cells was 20% (13%–28%) and 37% (36%–37%), respectively. At the knee load cell, the attenuated peak loads ranged from 62% to 81% for the Hybrid-III and 16% to 30% for the Mil-Lx.

Conclusions

Force attenuation characteristics in the booted vs unbooted configuration of the Mil-Lx were significantly different than force attenuation characteristics of the H3 and may better represent in vivo forces during vertical impact injuries, such as IED blasts. Hence for military relevant applications where boots are used, the Mil-Lx may provide a more conservative evaluation of lower extremity protection systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lower ExtremityLegHumansBiomechanical PhenomenaFootExplosionsAccidents, TrafficManikins

Autor:innen und Institutionen

  • Biomedical Engineering and Neurosurgery, Medical College of Wisconsin and VA Medical Center, 5000, W. National Avenue, Milwaukee, WI 53295, USA.
  • US Army Aeromedical Research Laboratory, PO Box 620577, Fort Rucker, AL 36362, USA.

ORCID-Profile: Frank A Pintar, Narayan Yoganandan

Förderung

  • Medical Research and Materiel Command

Zitieren

APA

Chirvi, S., Pintar, F. A., Yoganandan, N., & Joseph McEntire, B. (2023). Comparison of Axial Force Attenuation Characteristics in Two Different Lower Extremity Anthropomorphic Test Devices. Military Medicine. https://doi.org/10.1093/milmed/usad310

Vancouver

Chirvi S, Pintar FA, Yoganandan N, Joseph McEntire B. Comparison of Axial Force Attenuation Characteristics in Two Different Lower Extremity Anthropomorphic Test Devices. Military Medicine. 2023. doi:10.1093/milmed/usad310

BibTeX
@article{Chirvi2023,
  author = {Chirvi, Sajal and Pintar, Frank A and Yoganandan, Narayan and Joseph McEntire, B},
  title = {Comparison of Axial Force Attenuation Characteristics in Two Different Lower Extremity Anthropomorphic Test Devices},
  journal = {Military Medicine},
  year = {2023},
  doi = {10.1093/milmed/usad310}
}
Kostenlos starten →