The Ability of Military Critical Care Air Transport Members to Visually Estimate Percent Systolic Pressure Variation
Military Medicine · 2024
DOI: 10.1093/milmed/usad281 ↗Kurz gefasst
Fachartikel in der Zeitschrift Military Medicine, 2024. Verfasst von Mark A Cheney und 13 weiteren Autor:innen. Beteiligte Einrichtung: Center for Sustainment of Trauma and Readiness Skills, University of Cincinnati, Cincinnati, OH 45219, USA. Hauptthemen laut MEDLINE: Air Ambulances, Critical Care. Die Arbeit nennt 38 Literaturangaben.
Abstract (Originalsprache)
Introduction
Inappropriate fluid management during patient transport may lead to casualty morbidity. Percent systolic pressure variation (%SPV) is one of several technologies that perform a dynamic assessment of fluid responsiveness (FT-DYN). Trained anesthesia providers can visually estimate and use %SPV to limit the incidence of erroneous volume management decisions to 1-4%. However, the accuracy of visually estimated %SPV by other specialties is unknown. The aim of this article is to determine the accuracy of estimated %SPV and the incidence of erroneous volume management decisions for Critical Care Air Transport (CCAT) team members before and after training to visually estimate and utilize %SPV. Material and Methods In one sitting, CCAT team providers received didactics defining %SPV and indicators of fluid responsiveness and treatment with %SPV ≤7 and ≥14.5 defining a fluid nonresponsive and responsive patient, respectively; they were then shown ten 45-second training arterial waveforms on a simulated Propaq M portable monitor’s screen. Study subjects were asked to visually estimate %SPV for each arterial waveform and queried whether they would treat with a fluid bolus. After each training simulation, they were told the true %SPV. Seven days post-training, the subjects were shown a different set of ten 45-second testing simulations and asked to estimate %SPV and choose to treat, or not. Nonparametric limits of agreement for differences between true and estimated %SPV were analyzed using Bland–Altman graphs. In addition, three errors were defined: (1) %SPV visual estimate errors that would label a volume responsive patient as nonresponsive, or vice versa; (2) incorrect treatment decisions based on estimated %SPV (algorithm application errors); and (3) incorrect treatment decisions based on true %SPV (clinically significant treatment errors). For the training and testing simulations, these error rates were compared between, and within, provider groups.
Results
Sixty-one physicians (MDs), 64 registered nurses (RNs), and 53 respiratory technicians (RTs) participated in the study. For testing simulations, the incidence and 95% CI for %SPV estimate errors with sufficient magnitude to result in a treatment error were 1.4% (0.5%, 3.2%), 1.6% (0.6%, 3.4%), and 4.1% (2.2%, 6.9%) for MDs, RNs, and RTs, respectively. However, clinically significant treatment errors were statistically more common for all provider types, occurring at a rate of 7%, 10%, and 23% (all P < .05). Finally, students did not show clinically relevant reductions in their errors between training and testing simulations.
Conclusions
Although most practitioners correctly visually estimated %SPV and all students completed the training in interpreting and applying %SPV, all groups persisted in making clinically significant treatment errors with moderate to high frequency. This suggests that the treatment errors were more often driven by misapplying FT-DYN algorithms rather than by inaccurate visual estimation of %SPV. Furthermore, these errors were not responsive to training, suggesting that a decision-making cognitive aid may improve CCAT teams’ ability to apply FT-DYN technologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Center for Sustainment of Trauma and Readiness Skills, University of Cincinnati, Cincinnati, OH 45219, USA.
- Department of Anesthesiology, University of Cincinnati, Cincinnati, OH 45219, USA.
- Air Force Research Laboratory, Wright-Patterson Air Force Base, Dayton, OH 45324, USA.
- Department of Emergency Medicine, University of Cincinnati, Cincinnati, OH 45219, USA.
- United States Air Force En Route Care Research Center, 59th Medical Wing, Science and Technology, Lackland AFB TX 78236, USA.
- Department of Emergency Medicine, Wright State University, Dayton, OH 45324, USA.
ORCID-Profile: Mark A Cheney
Zitieren
APA
Cheney, M. A., Smith, M. P., Burkhardt, J. N., Davis, W. T., Brown, D. J., Horn, C., Hare, J., Alderman, M., Nelson, E., Proctor, M., Goodman, M., Sams, V., Thiele, R., & Strilka, R. J. (2024). The Ability of Military Critical Care Air Transport Members to Visually Estimate Percent Systolic Pressure Variation. Military Medicine. https://doi.org/10.1093/milmed/usad281
Vancouver
Cheney MA, Smith MP, Burkhardt JN, Davis WT, Brown DJ, Horn C, et al. The Ability of Military Critical Care Air Transport Members to Visually Estimate Percent Systolic Pressure Variation. Military Medicine. 2024. doi:10.1093/milmed/usad281
BibTeX
@article{Cheney2024,
author = {Cheney, Mark A and Smith, Maia P and Burkhardt, Joshua N and Davis, William T and Brown, Daniel J and Horn, Christopher and Hare, Jonathan and Alderman, Mark and Nelson, Eric and Proctor, Melissa and Goodman, Michael and Sams, Valerie and Thiele, Robert and Strilka, Richard J},
title = {The Ability of Military Critical Care Air Transport Members to Visually Estimate Percent Systolic Pressure Variation},
journal = {Military Medicine},
year = {2024},
doi = {10.1093/milmed/usad281}
}
EUVIMED