EUVIMEDEUVIMED entdecken
Crossref

Regional Strain Response of an Anatomically Accurate Human Finite Element Head Model Under Frontal Versus Lateral Loading

Tyler F Rooks, Valeta Carol Chancey, Jamie L Baisden, Narayan Yoganandan iD

Military Medicine · 2023

DOI: 10.1093/milmed/usad178 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Military Medicine, 2023. Verfasst von Tyler F Rooks und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA. Hauptthemen laut MEDLINE: Head, Brain Injuries. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: U.S. Army Medical Research and Development Command.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Because brain regions are responsible for specific functions, regional damage may cause specific, predictable symptoms. However, the existing brain injury criteria focus on whole brain response. This study developed and validated a detailed human brain computational model with sufficient fidelity to include regional components and demonstrate its feasibility to obtain region-specific brain strains under selected loading.

Methods

Model development used the Simulated Injury Monitor (SIMon) model as a baseline. Each SIMon solid element was split into 8, with each shell element split into 4. Anatomical regions were identified from FreeSurfer fsaverage neuroimaging template. Material properties were obtained from literature. The model was validated against experimental intracranial pressure, brain–skull displacement, and brain strain data. Model simulations used data from laboratory experiments with a rigid arm pendulum striking a helmeted head–neck system. Data from impact tests (6 m/s) at 2 helmet sites (front and left) were used.

Results

Model validation showed good agreement with intracranial pressure response, fair to good agreement with brain–skull displacement, and good agreement for brain strain. CORrelation Analysis scores were between 0.72 and 0.93 for both maximum principal strain (MPS) and shear strain. For frontal impacts, regional MPS was between 0.14 and 0.36 (average of left and right hemispheres). For lateral impacts, MPS was between 0.20 and 0.48 (left hemisphere) and between 0.22 and 0.51 (right hemisphere). For frontal impacts, regional cumulative strain damage measure (CSDM20) was between 0.01 and 0.87. For lateral impacts, CSDM20 was between 0.36 and 0.99 (left hemisphere) and between 0.09 and 0.93 (right hemisphere).

Conclusions

Recognizing that neural functions are related to anatomical structures and most model-based injury metrics focus on whole brain response, this study developed an anatomically accurate human brain model to capture regional responses. Model validation was comparable with current models. The model provided sufficient anatomical detail to describe brain regional responses under different impact conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HeadBrain InjuriesHumansFinite Element AnalysisBrainIntracranial PressureBiomechanical Phenomena

Autor:innen und Institutionen

  • Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
  • Injury Biomechanics and Protection Group, U.S. Army Aeromedical Research Laboratory, Fort Rucker, AL 36362, USA.

ORCID-Profile: Narayan Yoganandan

Förderung

  • U.S. Army Medical Research and Development Command

Zitieren

APA

Rooks, T. F., Chancey, V. C., Baisden, J. L., & Yoganandan, N. (2023). Regional Strain Response of an Anatomically Accurate Human Finite Element Head Model Under Frontal Versus Lateral Loading. Military Medicine. https://doi.org/10.1093/milmed/usad178

Vancouver

Rooks TF, Chancey VC, Baisden JL, Yoganandan N. Regional Strain Response of an Anatomically Accurate Human Finite Element Head Model Under Frontal Versus Lateral Loading. Military Medicine. 2023. doi:10.1093/milmed/usad178

BibTeX
@article{Rooks2023,
  author = {Rooks, Tyler F and Chancey, Valeta Carol and Baisden, Jamie L and Yoganandan, Narayan},
  title = {Regional Strain Response of an Anatomically Accurate Human Finite Element Head Model Under Frontal Versus Lateral Loading},
  journal = {Military Medicine},
  year = {2023},
  doi = {10.1093/milmed/usad178}
}
Kostenlos starten →