Fachartikel in der Zeitschrift Military Medicine, online erschienen am 15.12.2022. Verfasst von Chelsea Smith und 3 weiteren Autor:innen. Beteiligte Einrichtung: Royal Australian Army Medical Corps, Australian Army, Townsville, QLD 4811, Australia. Hauptthemen laut MEDLINE: Military Personnel, Postural Balance. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
Prevention of musculoskeletal injury is vital to the readiness, performance, and health of military personnel with the use of specialized systems (e.g., force plates) to assess risk and/or physical performance of interest. This study aimed to identify the reliability of one specialized system during standard assessments in military personnel.
Methods
Sixty-two male and ten female Australian Army soldiers performed a two-leg countermovement jump (CMJ), one-leg CMJ, one-leg balance, and one-arm plank assessments using a Sparta Science force plate system across three testing sessions. Sparta Science (e.g., total Sparta, balance and plank scores, jump height, and injury risk) and biomechanical (e.g., average eccentric rate of contraction, average concentric force, and sway velocity) variables were recorded for all sessions. Mean ± SD, intraclass correlation coefficients (ICCs), coefficient of variation, and bias and limits of agreement were calculated for all variables.
Results
Mean results were similar between sessions 2 and 3 (P > .05). The relative reliability for the Sparta Science (ICC = 0.28-0.91) and biomechanical variables (ICC = 0.03-0.85) was poor to excellent. The mean absolute reliability (coefficient of variation) for Sparta Science variables was similar to or lower than that of the biomechanical variables during the CMJ (1-10% vs. 3-7%), one-leg balance (4-6% vs. 9-14%), and one-arm plank (5-7% vs. 12-17%) assessments. The mean bias for most variables was small (<5% of the mean), while the limits of agreement varied with most unacceptable (±6-87% of the mean).
Conclusions
The reliability of most Sparta Science and biomechanical variables during standard assessments was moderate to good. The typical variability in metrics documented will assist practitioners with the use of emerging technology to monitor and assess injury risk and/or training interventions in military personnel.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Royal Australian Army Medical Corps, Australian Army, Townsville, QLD 4811, Australia.
- College of Medicine and Dentistry, James Cook University, Townsville, QLD 4811, Australia.
- Sport and Exercise Science, James Cook University, Townsville, QLD 4811, Australia.
- Australian Institute of Tropical Health and Medicine, James Cook University, Townsville, QLD 4811, Australia.
ORCID-Profile: Chelsea Smith, Kenji Doma, Brian Heilbronn, Anthony Leicht
Zitieren
APA
Smith, C., Doma, K., Heilbronn, B., & Leicht, A. (2023). Reliability of Force Plate Metrics During Standard Jump, Balance, and Plank Assessments in Military Personnel. Military Medicine, 188(7-8), e2058-e2066. https://doi.org/10.1093/milmed/usac387
Vancouver
Smith C, Doma K, Heilbronn B, Leicht A. Reliability of Force Plate Metrics During Standard Jump, Balance, and Plank Assessments in Military Personnel. Military Medicine. 2023;188(7-8):e2058-e2066. doi:10.1093/milmed/usac387
BibTeX
@article{Smith2023,
author = {Smith, Chelsea and Doma, Kenji and Heilbronn, Brian and Leicht, Anthony},
title = {Reliability of Force Plate Metrics During Standard Jump, Balance, and Plank Assessments in Military Personnel},
journal = {Military Medicine},
year = {2023},
volume = {188},
number = {7-8},
pages = {e2058--e2066},
doi = {10.1093/milmed/usac387}
}
EUVIMED