EUVIMEDEUVIMED entdecken
Crossref

Preservation of Vascular Tissues From Shrinkage During X-Ray 3D-CECT Imaging

Lara Mazy, Grzegorz Pyka, Jeroen Soete iD, Martine Wevers, Greet Kerckhofs iD

Microscopy and Microanalysis · 12.10.2026 · 32 (6)

DOI: 10.1093/mam/ozag120 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 29.10.2026. Verfasst von Lara Mazy und 4 weiteren Autor:innen. Beteiligte Einrichtung: MEED Department, Institute of Mechanics, Materials and Civil Engineering, UCLouvain, Place du Levant 2 - box L5.04.01, 1348 Louvain-la-Neuve, Belgium. Hauptthemen laut MEDLINE: X-Ray Microtomography, Aorta, Imaging, Three-Dimensional. Die Arbeit nennt 41 Literaturangaben. Gefördert von: FWO, FWF, Research Foundation Flanders.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Preventing shrinkage of biological tissues during X-ray microfocus computed tomography (3D-microCT) is essential to prevent motion artifacts and microstructural changes, which is particularly problematic in the context of 4D-microCT. While liquid immersion and parafilm wrapping are commonly used to limit dehydration, both methods present limitations for combining them with in situ mechanical testing. This work introduces an in-house environmental stage capable of controlling temperature and relative humidity (RH) around the sample during imaging with vapor phase method. Using 3D-microCT with stained porcine aortic tissues, we assessed the impact of temperature and RH on tissue volume change over time. Results demonstrated that both temperature and RH significantly influence shrinkage rate, with temperature playing a dominant role. Volume loss increased with decreasing RH and increasing temperature. Furthermore, shrinkage was heterogeneous and was particularly pronounced at cut tissue edges. Among all tested conditions, 10°C combined with 95% RH best preserved tissue hydration, showing minimal shrinkage and reduced motion artifacts. Validation at higher spatial resolution confirmed that this controlled environment enables prolonged acquisitions while maintaining image quality superior to imaging under ambient conditions. This study highlights the importance of environmental control during microCT imaging of soft tissues and provides a quantitative framework for selecting optimal atmospheric conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

X-Ray MicrotomographyAortaImaging, Three-DimensionalAnimalsSwineHumidityTemperature

Stichwörter der Autor:innen

biological tissuescontrast enhancementdehydrationenvironmental stagemechanical propertiesmicroCT

Autor:innen und Institutionen

  • MEED Department, Institute of Mechanics, Materials and Civil Engineering, UCLouvain, Place du Levant 2 - box L5.04.01, 1348 Louvain-la-Neuve, Belgium.
  • Department of Materials Engineering, KU Leuven, Kasteelpark Arenberg 44 - box 2450, 3001 Leuven, Belgium.
  • Pole of Morphology, Institute of Experimental and Clinical Research, UCLouvain, Avenue E. Mounier 52 - box B1.52.04, 1200 Brussels, Belgium.
  • Prometheus, Division of Skeletal Tissue Engineering, KU Leuven, O&N I Herestraat 49 - box 813, 3000 Leuven, Belgium.

ORCID-Profile: Jeroen Soete, Greet Kerckhofs

Förderung

  • FWO
  • FWF
  • Research Foundation Flanders
  • FSR
  • Fonds de Recherche Spécial Jeunes Acad´emiques
  • Fédération Wallonie-Bruxelles
  • Action de Recherche Concertée
  • ARC

Zitieren

APA

Mazy, L., Pyka, G., Soete, J., Wevers, M., & Kerckhofs, G. (2026). Preservation of Vascular Tissues From Shrinkage During X-Ray 3D-CECT Imaging. Microscopy and Microanalysis, 32(6). https://doi.org/10.1093/mam/ozag120

Vancouver

Mazy L, Pyka G, Soete J, Wevers M, Kerckhofs G. Preservation of Vascular Tissues From Shrinkage During X-Ray 3D-CECT Imaging. Microscopy and Microanalysis. 2026;32(6). doi:10.1093/mam/ozag120

BibTeX
@article{Mazy2026,
  author = {Mazy, Lara and Pyka, Grzegorz and Soete, Jeroen and Wevers, Martine and Kerckhofs, Greet},
  title = {Preservation of Vascular Tissues From Shrinkage During X-Ray 3D-CECT Imaging},
  journal = {Microscopy and Microanalysis},
  year = {2026},
  volume = {32},
  number = {6},
  doi = {10.1093/mam/ozag120}
}
Kostenlos starten →