Error-Guaranteed Compression with Preservation of Downstream Quantities for Electron Microscopy
Microscopy and Microanalysis · 01.07.2026 · 32 (4)
DOI: 10.1093/mam/ozag084 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 31.07.2026. Verfasst von Jaemoon Lee und 11 weiteren Autor:innen. Beteiligte Einrichtung: Computer Science and Mathematics Division, Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37830, USA. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
Recent electron microscopy workflows, particularly 4D Scanning Transmission Electron Microscopy (4D STEM), generate massive data volumes, sometimes exceeding tens of terabytes per dataset. This growth is outpacing improvements in storage, network, and I/O bandwidths. Although lossless compression offers a viable solution, it is often limited by modest compression ratios. Lossy compression offers an alternative; however, compression errors can propagate to downstream analyses. The goal is therefore to deploy a compression method that preserves essential data features while defining a suitable metric. In this paper, we present a moment-preserving compression workflow combining multigrid adaptive reduction (MGARD) with a constraint satisfaction technique. MGARD provides mathematically guaranteed error bounds on raw data, while a constraint satisfaction method rectifies decompressed data to strictly preserve selected statistical moments in diffraction space. This allows moment-derived observables, such as Center-of-Mass (COM) measurements, to be recovered consistently from the corrected tensor. Furthermore, we propose a frequency-domain reliability criterion in raw diffraction space to evaluate the acceptable accuracy limits. Experiments on 4D STEM datasets demonstrate that this moment-preserving adjustment substantially reduces errors in targeted downstream quantities, providing a practical path toward compressed 4D STEM data compatible with downstream microscopy analysis.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Computer Science and Mathematics Division, Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37830, USA.
- Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37830, USA.
- Computational Sciences and Engineering Division, Oak Ridge National Laboratory, 1 Bethel Valley Road, Oak Ridge, TN 37830, USA.
- Department of Computer and Information Science and Engineering, University of Florida, 1889 Museum Road, Gainesville, FL 32611, USA.
- Department of Computer Science, University of Oregon, 1202 University of Oregon, Eugene, OR 97403, USA.
- Department of Electrical and Computer Engineering, New Jersey Institute of Technology, 154 Summit Street, Newark, NJ 07102, USA.
ORCID-Profile: Jaemoon Lee, Andrew R Lupini, Debangshu Mukherjee, Alexis N Williams
Zitieren
APA
Lee, J., Hoglund, E. R., Gong, Q., Lupini, A. R., Mukherjee, D., Williams, A. N., Rangarajan, A., Chen, J., Liu, Q., Ranka, S., Yan, N., & Klasky, S. (2026). Error-Guaranteed Compression with Preservation of Downstream Quantities for Electron Microscopy. Microscopy and Microanalysis, 32(4). https://doi.org/10.1093/mam/ozag084
Vancouver
Lee J, Hoglund ER, Gong Q, Lupini AR, Mukherjee D, Williams AN, et al. Error-Guaranteed Compression with Preservation of Downstream Quantities for Electron Microscopy. Microscopy and Microanalysis. 2026;32(4). doi:10.1093/mam/ozag084
BibTeX
@article{Lee2026,
author = {Lee, Jaemoon and Hoglund, Eric R and Gong, Qian and Lupini, Andrew R and Mukherjee, Debangshu and Williams, Alexis N and Rangarajan, Anand and Chen, Jieyang and Liu, Qing and Ranka, Sanjay and Yan, Nick and Klasky, Scott},
title = {Error-Guaranteed Compression with Preservation of Downstream Quantities for Electron Microscopy},
journal = {Microscopy and Microanalysis},
year = {2026},
volume = {32},
number = {4},
doi = {10.1093/mam/ozag084}
}
EUVIMED