FIB Tailoring of SiNx Membranes for Enhanced-Clarity In Situ Closed-Cell TEM

Changjie Huang iD, Florian Chabanais iD, Risha Achaiah Iythichanda iD, Leiqiang Qin iD, Johanna Rosen, Per O Å Persson iD, Justinas Palisaitis iD

Microscopy and Microanalysis · 01.07.2026 · 32 (4)

DOI: 10.1093/mam/ozag068 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 17.07.2026. Verfasst von Changjie Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Thin Film Physics Division, Department of Physics, Chemistry and Biology (IFM), Linköping University, Linköping SE-581 83, Sweden. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In situ closed-cell transmission electron microscopy (TEM) enables real-time observation of dynamic processes, offering insight into the evolution of materials under realistic environments. However, the thickness of the silicon nitride membranes, enclosing the sample environment, critically limits image quality and analytical sensitivity. In this work, two focused ion beam (FIB) milling strategies are systematically investigated: (I) to enable precise thinning of membranes, and (II) to perforate, while preserving their functional integrity in both cases. For membrane thinning (I), an optimized set of FIB parameters, together with milling time calibration, is established to achieve reproducible thickness reduction. The milling behavior is found to depend primarily on the ion milling angle and membrane rotation. Milling angles ranging from normal to shallow incidence are examined, with the most uniform membrane morphologies obtained at intermediate angles. In addition, post-milling thermal treatment is shown to effectively mitigate ion implantation effects. For membrane perforation (II), localized membrane openings are fabricated via normal-incidence milling. The area of the openings is optimized to accommodate a range of sample types while maintaining compatibility with closed-cell operation. Based on these findings, FIB workflows are proposed to enhance the clarity and experimental flexibility of in situ closed-cell TEM studies.

Schlagwörter

Stichwörter der Autor:innen

in situ closed-cellSiNx membranefocused ion beamion milling

Autor:innen und Institutionen

  • Thin Film Physics Division, Department of Physics, Chemistry and Biology (IFM), Linköping University, Linköping SE-581 83, Sweden.
  • Materials Design Division, Department of Physics, Chemistry and Biology (IFM), Linköping University, Linköping SE-581 83, Sweden.

ORCID-Profile: Changjie Huang, Florian Chabanais, Risha Achaiah Iythichanda, Leiqiang Qin, Per O Å Persson, Justinas Palisaitis

Zitieren

APA

Huang, C., Chabanais, F., Achaiah Iythichanda, R., Qin, L., Rosen, J., Persson, P. O. Å., & Palisaitis, J. (2026). FIB Tailoring of SiNx Membranes for Enhanced-Clarity In Situ Closed-Cell TEM. Microscopy and Microanalysis, 32(4). https://doi.org/10.1093/mam/ozag068

Vancouver

Huang C, Chabanais F, Achaiah Iythichanda R, Qin L, Rosen J, Persson POÅ, et al. FIB Tailoring of SiNx Membranes for Enhanced-Clarity In Situ Closed-Cell TEM. Microscopy and Microanalysis. 2026;32(4). doi:10.1093/mam/ozag068

BibTeX
@article{Huang2026,
  author = {Huang, Changjie and Chabanais, Florian and Achaiah Iythichanda, Risha and Qin, Leiqiang and Rosen, Johanna and Persson, Per O Å and Palisaitis, Justinas},
  title = {FIB Tailoring of SiNx Membranes for Enhanced-Clarity In Situ Closed-Cell TEM},
  journal = {Microscopy and Microanalysis},
  year = {2026},
  volume = {32},
  number = {4},
  doi = {10.1093/mam/ozag068}
}
Kostenlos starten →