EUVIMEDEUVIMED entdecken
Crossref

Ultrastructural Characterization of Resin Embedded Biological Samples Using STEM-HAADF Mode

Bernd Zechmann

Microscopy and Microanalysis · 27.07.2026 · 32 (Supplement_1)

DOI: 10.1093/mam/ozag053.897 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 27.07.2026. Verfasst von Bernd Zechmann. Die Arbeit nennt 1 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For ultrastructural investigations resin embedded biological samples are most commonly imaged in TEM brightfield mode. In this mode the electron beam transmits through the sample. Non-scattered electrons that transmit through the sample and strike the camera appear bright whereas electrons that are reflected or absorbed by the sample and scattered electrons that don’t strike the camera appear black. The ultrastructure of the samples appears black and white on the final TEM brightfield image. Advanced TEMs can also be operated in scanning transmission electron microscopy (STEM) mode where the electron beam is much smaller and scans across the surface of the sample. For imaging purposes electrons that scatter at high angles can be detected with the high-angle annular dark field (HAADF) detector. The intensity of scattered electrons is directly proportional to the atomic number of the atoms in the samples. Thus, in the final image elements with high atomic mass appear brighter than elements with low atomic mass which appear darker. Ultrastructural investigations of resin embedded biological samples in STEM-HAADF mode are rare. In this study STEM-HAADF mode was used to image sections of resin embedded biological samples that did not receive post contrasting. The hypothesis was tested that image contrast and quality would be better in STEM-HAADF mode when compared to TEM brightfield mode. Different biological samples (algae cells, plant leaves, mouse brain and liver tissue) were prepared for TEM analysis by fixing them in 2.5% of glutaraldehyde followed by 1% osmium tetroxide in phosphate buffer. Samples were then rinsed in buffer, dehydrated in a series of acetone (50%, 70%, 90%, and 100%), infiltrated with EMBed812 epoxy resin and polymerized for 48h [1]. Resin blocks were trimmed (EM-TRIM, Leica Microsystems) and ultra-thin sections (80 nm) were sectioned with an EM UC7 ultramicrotome (Leica Microsystems). Sections were not treated with post-contrasting agents but directly imaged in STEM-HAADF or TEM brightfield mode with a Spectra 300C TEM (Thermo Fisher Scientific, Hillsboro, OR). For the final image in STEM-HAADF mode 300KeV with a convergence angle of 10.3 mrad, a camera length of 87 mm, and a collection angle range between 66 – 200 mrad were used. For STEM-HAADF images, resolution was set to 2048x2048 and dwell time to 10 µs (Fig. 1a). Images taken in STEM-HAADF mode were inverted (Fig. 1b) to make them appear like images taken in traditional bright field TEM mode (Fig. 1c). For TEM brightfield images a series of 10 images (exposure time 1 second each) were taken with a Ceta D camera (Thermo Fisher Scientific, Hillsboro, OR) and were overlaid to one image (Fig. 1c). STEM-HAADF mode yielded better image quality in terms of contrast, brightness, signal-to-noise ratio, and perceived image quality of sections that were not post-contrasted (Fig. 1b, 2a-d) when compared to TEM brightfield images (Fig 1c). Image analysis confirmed that, when compared to brightfield TEM mode, all of these parameters scored higher in STEM-HAADF mode (data not shown). Organelles such as chloroplasts, mitochondria, nuclei, vacuoles were clearly visible in STEM-HAADF mode (Fig. 2). Even fine ultrastructural features such as thylakoids of chloroplasts (Fig. 2b), cristae in mitochondria (Fig. 1b, 2c), and ribosomes on rough endoplasmic reticulum were well visible (Fig. 2c). In summary, STEM-HAADF mode was well suited to image sections of biological samples that did not receive post contrasting such as algae, plant leaves, mouse brain and liver. Additionally, image analysis confirmed that images taken in STEM-HAADF mode yielded better image quality than images taken in TEM-brightfield mode. Micrographs of a mouse brain cell taken in STEM-HAADF mode (a, b) and TEM brightfield mode (c). In images taken in STEM-HAADF mode (a) structures with high atomic mass appear bright and structures with low atomic mass appear darker. The inverted STEM-HAADF image (b) yielded slightly better image quality than the image taken in TEM brightfield mode (c). Ax=Axon, M=Mitochondrion. Bars=0.5nm. Inverted STEM-HAADF micrographs of a) Chlorella sorokiniana with a large chloroplast (C) containing starch (St), a mitochondrion (arrowhead), and a nucleus (N), b) leaf section of Nicotiana tabacum with several chloroplasts (C), a mitochondrion (arrowhead), a large nucleus (N), and a vacuole (V), c) mouse liver cell with several mitochondria (M), a nucleus (N), and a well-defined network of rough endoplasmic reticulum (arrows), and d) mouse brain cell with axons (asterisks), dendrites (D), and mitochondria (arrowheads). Bars=1µm.

Zitieren

APA

Zechmann, B. (2026). Ultrastructural Characterization of Resin Embedded Biological Samples Using STEM-HAADF Mode. Microscopy and Microanalysis, 32(Supplement_1). https://doi.org/10.1093/mam/ozag053.897

Vancouver

Zechmann B. Ultrastructural Characterization of Resin Embedded Biological Samples Using STEM-HAADF Mode. Microscopy and Microanalysis. 2026;32(Supplement_1). doi:10.1093/mam/ozag053.897

BibTeX
@article{Zechmann2026,
  author = {Zechmann, Bernd},
  title = {Ultrastructural Characterization of Resin Embedded Biological Samples Using STEM-HAADF Mode},
  journal = {Microscopy and Microanalysis},
  year = {2026},
  volume = {32},
  number = {Supplement_1},
  doi = {10.1093/mam/ozag053.897}
}
Kostenlos starten →