EUVIMEDEUVIMED entdecken
Crossref

Quantitative 4DSTEM-EMCD Analysis at Atomic Resolution

Sharath Kumar Manjeshwar Sathyanath, Anna L Ravensburg, Vassilios Kapaklis, Björgvin Hjörvarsson, Klaus Leifer

Microscopy and Microanalysis · 27.07.2026 · 32 (Supplement_1)

DOI: 10.1093/mam/ozag053.860 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 27.07.2026. Verfasst von Sharath Kumar Manjeshwar Sathyanath und 4 weiteren Autor:innen. Die Arbeit nennt 4 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Structure and electronic structure of interfaces determine their magnetic properties in modern quantum materials. Yet, X-ray and neutron-based analysis techniques, albeit their fantastic contributions to the field of magnetism, cannot give the real space image of the magnetic properties. Recently, two papers, one based on electron holography and the other one using a differential phase contrast method, opened the door to the atomic scale analysis of magnetic materials [1, 2]. A third technique, electron magnetic circular dichroism (EMCD), enables the analysis of magnetic properties, and in particular the analysis of the magnetic orbital moment to magnetic spin moment ml/ms, which is an important magnitude determining the properties of magnetic interfaces. Atomic scale analysis of magnetic materials could be equally shown using the EMCD technique [3, 4]. Though, when the analysis of magnetic interfaces is targeted, the magnetization data must be quantitative and the quantitative data must be extractable from single atomic lattice planes. In this work, we describe the development of single plane resolved EMCD work as well as a quantitative analysis of a magnetic interface with the same resolution. For this purpose, we have developed a method that lifts most ambivalences present in the EMCD measurements and optimizes signal/noise ratio. To achieve atomic resolution, we first systematically study the evolution of the STEM-EMCD signals as a function of convergence angles. We find conditions where at convergence angles corresponding to atomic resolution, quantitative EMCD work is achieved and the ml/ms ratio can be extracted from such data. The results are in good agreement with the predictions from EMCD simulations. In the next step, we apply those conditions to the atomic resolution analysis of an Fe crystal with highest crystalline perfection. As a result, we not only obtain atomic plane resolution but the S/N ratio is high enough to analyze EMCD signals on lattice plane positions and in between lattice planes. We interpret those results using the simulation of the EMCD signal. Finally, we use the single plane EMCD setup to analyze a magnetic interface between an Fe film and the oxide substrate. The high quantitative resolution shows as a sharp increase of the magnetic EMCD signal at the interface. The quantitative profiles of L3, L2 EMCD difference signal a well as the ml/ms ratio at the interface and in the immediate vicinity of the interface will be discussed.

Zitieren

APA

Sathyanath, S. K. M., Ravensburg, A. L., Kapaklis, V., Hjörvarsson, B., & Leifer, K. (2026). Quantitative 4DSTEM-EMCD Analysis at Atomic Resolution. Microscopy and Microanalysis, 32(Supplement_1). https://doi.org/10.1093/mam/ozag053.860

Vancouver

Sathyanath SKM, Ravensburg AL, Kapaklis V, Hjörvarsson B, Leifer K. Quantitative 4DSTEM-EMCD Analysis at Atomic Resolution. Microscopy and Microanalysis. 2026;32(Supplement_1). doi:10.1093/mam/ozag053.860

BibTeX
@article{Sathyanath2026,
  author = {Sathyanath, Sharath Kumar Manjeshwar and Ravensburg, Anna L and Kapaklis, Vassilios and Hjörvarsson, Björgvin and Leifer, Klaus},
  title = {Quantitative 4DSTEM-EMCD Analysis at Atomic Resolution},
  journal = {Microscopy and Microanalysis},
  year = {2026},
  volume = {32},
  number = {Supplement_1},
  doi = {10.1093/mam/ozag053.860}
}
Kostenlos starten →